etim 5.0 · Class
EC002580Flow monitoring equipment
Definition not reported by the standard.
Synonyms: Flow monitoring equipment
- Stable identifier
etim:EC002580- Permalink
- /classifications/etim/5.0/EC002580
- Class revision in the standard
- 4
Properties (28)
| Code | Label (EN) | Label (DE) | Type | Unit | Allowed values |
|---|---|---|---|---|---|
| EF007245 | Suitable for liquids | Suitable for liquidsen fallback: no German translation | logical | — | — |
| EF007249 | Suitable for gases | Suitable for gasesen fallback: no German translation | logical | — | — |
| EF007372 | Measuring head in device integrated | Measuring head in device integrateden fallback: no German translation | logical | — | — |
| EF007371 | Measuring head included | Measuring head includeden fallback: no German translation | logical | — | — |
| EF006950 | Type of process connection | Type of process connectionen fallback: no German translation | alphanumeric | — |
|
| EF006937 | Number of switching points | Number of switching pointsen fallback: no German translation | numeric | — | — |
| EF007127 | Adjustable setting value for flow for liquids | Adjustable setting value for flow for liquidsen fallback: no German translation | range | m/s | — |
| EF007128 | Adjustable setting value for flow for gases | Adjustable setting value for flow for gasesen fallback: no German translation | range | m/s | — |
| EF007104 | Wire break- or measuring circuit monitoring | Wire break- or measuring circuit monitoringen fallback: no German translation | logical | — | — |
| EF007506 | Temperature medium | Temperature mediumen fallback: no German translation | range | °C | — |
| EF007505 | Ambient temperature for evaluation electronic | Ambient temperature for evaluation electronicen fallback: no German translation | range | °C | — |
| EF007107 | Compressive strength measuring head | Compressive strength measuring headen fallback: no German translation | numeric | bar | — |
| EF003978 | Rated control supply voltage Us at AC 50HZ | Rated control supply voltage Us at AC 50HZen fallback: no German translation | range | V | — |
| EF003979 | Rated control supply voltage Us at AC 60HZ | Rated control supply voltage Us at AC 60HZen fallback: no German translation | range | V | — |
| EF003980 | Rated control supply voltage Us at DC | Rated control supply voltage Us at DCen fallback: no German translation | range | V | — |
| EF008242 | Voltage type for actuating | Voltage type for actuatingen fallback: no German translation | alphanumeric | — |
|
| EF001106 | Number of normally closed contacts | Number of normally closed contactsen fallback: no German translation | numeric | — | — |
| EF001105 | Number of normally open contacts | Number of normally open contactsen fallback: no German translation | numeric | — | — |
| EF001107 | Number of change-over contacts | Number of change-over contactsen fallback: no German translation | numeric | — | — |
| EF007508 | Transistor output | Transistor outputen fallback: no German translation | logical | — | — |
| EF008201 | Delay-on energization time | Delay-on energization timeen fallback: no German translation | range | s | — |
| EF007509 | Trend output (not linear, analog) | Trend output (not linear, analog)en fallback: no German translation | logical | — | — |
| EF003961 | Type of electric connection | Type of electric connectionen fallback: no German translation | alphanumeric | — |
|
| EF000008 | Width | Widthen fallback: no German translation | numeric | mm | — |
| EF000040 | Height | Heighten fallback: no German translation | numeric | mm | — |
| EF000049 | Depth | Depthen fallback: no German translation | numeric | mm | — |
| EF007464 | Degree of protection (IP) of evaluation electronic | Degree of protection (IP) of evaluation electronicen fallback: no German translation | alphanumeric | — |
|
| EF007465 | Degree of protection (IP) of measuring head | Degree of protection (IP) of measuring headen fallback: no German translation | alphanumeric | — |
|
Requirement levels are not part of this standard and are not shown.
Change history
Per-class history is not reported. Compare releases to see what changed between versions.