Skip to content
Sign in

ETIM technical information model, English master (unofficial mirror)

License:ODC-By-1.0Community · the product.cloud project (unofficial mirror)Updated · latest release 10.0
  • Validated
  • Community maintained
About access and trust
Open
Immediately usable under the displayed license. Access is separate from the license.
License
ODC-By-1.0 governs use, including for open repositories.
You
No entitlement needed: the content is open.
Validated
Required rulepack checks passed for the named revision.
Community maintained
Maintained by contributors, not the named product authority.
Release 5.0 — pinned
Follow0 Use repository
Hierarchy

etim 5.0 · Class

EC002580Flow monitoring equipment

Definition not reported by the standard.

Synonyms: Flow monitoring equipment

Stable identifier
etim:EC002580
Class revision in the standard
4

Properties (28)

Properties of EC002580 in English with German for comparison
CodeLabel (EN)Label (DE)TypeUnitAllowed values
EF007245Suitable for liquidsSuitable for liquidsen fallback: no German translationlogical——
EF007249Suitable for gasesSuitable for gasesen fallback: no German translationlogical——
EF007372Measuring head in device integratedMeasuring head in device integrateden fallback: no German translationlogical——
EF007371Measuring head includedMeasuring head includeden fallback: no German translationlogical——
EF006950Type of process connectionType of process connectionen fallback: no German translationalphanumeric—
  • EV007343 Thread connection
  • EV009221 Insert connection
  • EV009393 Pipe connection
  • EV009242 Flange connection
  • EV000154 Other
  • EV000494 None
EF006937Number of switching pointsNumber of switching pointsen fallback: no German translationnumeric——
EF007127Adjustable setting value for flow for liquidsAdjustable setting value for flow for liquidsen fallback: no German translationrangem/s—
EF007128Adjustable setting value for flow for gasesAdjustable setting value for flow for gasesen fallback: no German translationrangem/s—
EF007104Wire break- or measuring circuit monitoringWire break- or measuring circuit monitoringen fallback: no German translationlogical——
EF007506Temperature mediumTemperature mediumen fallback: no German translationrange°C—
EF007505Ambient temperature for evaluation electronicAmbient temperature for evaluation electronicen fallback: no German translationrange°C—
EF007107Compressive strength measuring headCompressive strength measuring headen fallback: no German translationnumericbar—
EF003978Rated control supply voltage Us at AC 50HZRated control supply voltage Us at AC 50HZen fallback: no German translationrangeV—
EF003979Rated control supply voltage Us at AC 60HZRated control supply voltage Us at AC 60HZen fallback: no German translationrangeV—
EF003980Rated control supply voltage Us at DCRated control supply voltage Us at DCen fallback: no German translationrangeV—
EF008242Voltage type for actuatingVoltage type for actuatingen fallback: no German translationalphanumeric—
  • EV000460 AC
  • EV000461 DC
  • EV000509 AC/DC
EF001106Number of normally closed contactsNumber of normally closed contactsen fallback: no German translationnumeric——
EF001105Number of normally open contactsNumber of normally open contactsen fallback: no German translationnumeric——
EF001107Number of change-over contactsNumber of change-over contactsen fallback: no German translationnumeric——
EF007508Transistor outputTransistor outputen fallback: no German translationlogical——
EF008201Delay-on energization timeDelay-on energization timeen fallback: no German translationranges—
EF007509Trend output (not linear, analog)Trend output (not linear, analog)en fallback: no German translationlogical——
EF003961Type of electric connectionType of electric connectionen fallback: no German translationalphanumeric—
  • EV005757 Insulation piercing connection
  • EV005752 Spring clamp connection
  • EV003968 Flat plug-in connection
  • EV005755 Clip connection
  • EV005756 Soldering flag connection
  • EV003963 PCB connection
  • EV003987 Insulation displacement connection
  • EV000415 Screw connection
  • EV005758 Welding connection
  • EV000414 Plug-in connection
  • EV005754 Wrapped connection
  • EV000154 Other
EF000008WidthWidthen fallback: no German translationnumericmm—
EF000040HeightHeighten fallback: no German translationnumericmm—
EF000049DepthDepthen fallback: no German translationnumericmm—
EF007464Degree of protection (IP) of evaluation electronicDegree of protection (IP) of evaluation electronicen fallback: no German translationalphanumeric—
  • EV006404 IP00
  • EV006606 IP10
  • EV006607 IP12
  • EV006405 IP20
  • EV006406 IP21
  • EV006608 IP22
  • EV006407 IP23
  • EV006408 IP24
  • EV006409 IP2X
  • EV006410 IP30
  • EV006411 IP31
  • EV006412 IP32
  • EV006609 IP33
  • EV006413 IP34
  • EV006414 IP3X
  • EV006415 IP40
  • EV006416 IP41
  • EV006417 IP42
  • EV006610 IP43
  • EV006418 IP44
  • EV006611 IP45
  • EV006612 IP50
  • EV006613 IP52
  • EV006614 IP53
  • EV006419 IP54
  • EV006420 IP55
  • EV006615 IP56
  • EV006616 IP57
  • EV006617 IP58
  • EV006618 IP64
  • EV006421 IP65
  • EV008925 IP65/IP67
  • EV006422 IP66
  • EV006423 IP67
  • EV009289 IP67K
  • EV006619 IP68
  • EV006620 IPX0
  • EV006621 IPX4
  • EV006622 IPX7
  • EV000154 Other
EF007465Degree of protection (IP) of measuring headDegree of protection (IP) of measuring headen fallback: no German translationalphanumeric—
  • EV006404 IP00
  • EV006606 IP10
  • EV006607 IP12
  • EV006405 IP20
  • EV006406 IP21
  • EV006608 IP22
  • EV006407 IP23
  • EV006408 IP24
  • EV006409 IP2X
  • EV006410 IP30
  • EV006411 IP31
  • EV006412 IP32
  • EV006609 IP33
  • EV006413 IP34
  • EV006414 IP3X
  • EV006415 IP40
  • EV006416 IP41
  • EV006417 IP42
  • EV006610 IP43
  • EV006418 IP44
  • EV006611 IP45
  • EV006612 IP50
  • EV006613 IP52
  • EV006614 IP53
  • EV006419 IP54
  • EV006420 IP55
  • EV006615 IP56
  • EV006616 IP57
  • EV006617 IP58
  • EV006618 IP64
  • EV006421 IP65
  • EV008925 IP65/IP67
  • EV006422 IP66
  • EV006423 IP67
  • EV009289 IP67K
  • EV006619 IP68
  • EV006620 IPX0
  • EV006621 IPX4
  • EV006622 IPX7
  • EV000154 Other

Requirement levels are not part of this standard and are not shown.

Change history

Per-class history is not reported. Compare releases to see what changed between versions.

    Data: ETIM International · ODC-By-1.0