etim 5.0 · Class
EC001445Residual current monitoring relay
Definition not reported by the standard.
Synonyms: Current monitoring relay, Relay, Residual current monitoring relay
- Stable identifier
etim:EC001445- Permalink
- /classifications/etim/5.0/EC001445
- Class revision in the standard
- 4
Properties (21)
| Code | Label (EN) | Label (DE) | Type | Unit | Allowed values |
|---|---|---|---|---|---|
| EF003961 | Type of electric connection | Type of electric connectionen fallback: no German translation | alphanumeric | — |
|
| EF003978 | Rated control supply voltage Us at AC 50HZ | Rated control supply voltage Us at AC 50HZen fallback: no German translation | range | V | — |
| EF003979 | Rated control supply voltage Us at AC 60HZ | Rated control supply voltage Us at AC 60HZen fallback: no German translation | range | V | — |
| EF003980 | Rated control supply voltage Us at DC | Rated control supply voltage Us at DCen fallback: no German translation | range | V | — |
| EF008242 | Voltage type for actuating | Voltage type for actuatingen fallback: no German translation | alphanumeric | — |
|
| EF003340 | With detachable clamps | With detachable clampsen fallback: no German translation | logical | — | — |
| EF000030 | Function | Functionen fallback: no German translation | alphanumeric | — |
|
| EF003977 | Rated voltage | Rated voltageen fallback: no German translation | range | V | — |
| EF001663 | Rated frequency | Rated frequencyen fallback: no German translation | range | Hz | — |
| EF008204 | Response value amperage 1 | Response value amperage 1en fallback: no German translation | range | mA | — |
| EF008205 | Response value amperage 2 | Response value amperage 2en fallback: no German translation | range | mA | — |
| EF008190 | Min. adjustable delay-on energization time | Min. adjustable delay-on energization timeen fallback: no German translation | numeric | s | — |
| EF008189 | Max. permitted delay-on energization time | Max. permitted delay-on energization timeen fallback: no German translation | numeric | s | — |
| EF003424 | Indication of difference current | Indication of difference currenten fallback: no German translation | logical | — | — |
| EF003423 | Error registration possible | Error registration possibleen fallback: no German translation | logical | — | — |
| EF008255 | Number of contacts as normally closed contact | Number of contacts as normally closed contacten fallback: no German translation | numeric | — | — |
| EF008256 | Number of contacts as normally open contact | Number of contacts as normally open contacten fallback: no German translation | numeric | — | — |
| EF008257 | Number of contacts as change-over contact | Number of contacts as change-over contacten fallback: no German translation | numeric | — | — |
| EF000008 | Width | Widthen fallback: no German translation | numeric | mm | — |
| EF000040 | Height | Heighten fallback: no German translation | numeric | mm | — |
| EF000049 | Depth | Depthen fallback: no German translation | numeric | mm | — |
Requirement levels are not part of this standard and are not shown.
Change history
Per-class history is not reported. Compare releases to see what changed between versions.