Skip to content
Sign in

ETIM technical information model, English master (unofficial mirror)

License:ODC-By-1.0Community · the product.cloud project (unofficial mirror)Updated · latest release 10.0
  • Validated
  • Community maintained
About access and trust
Open
Immediately usable under the displayed license. Access is separate from the license.
License
ODC-By-1.0 governs use, including for open repositories.
You
No entitlement needed: the content is open.
Validated
Required rulepack checks passed for the named revision.
Community maintained
Maintained by contributors, not the named product authority.
Release 7.0 — pinned
Follow0 Use repository
Hierarchy

etim 7.0 · Class

EC012035Heat pump (air/water) split type

Definition not reported by the standard.

Synonyms: Heat pump, Heat pump (air/water) split type, Heat pump (water/water)

Stable identifier
etim:EC012035
Class revision in the standard
2

Properties (63)

Properties of EC012035 in English
CodeLabel (EN)TypeUnitAllowed values
EF000010Modelalphanumeric—
  • EV000086 Complete
  • EV023546 Outdoor unit
  • EV023547 Indoor unit
EF025889Heating capacity at 7/35°C according to EN 14511numerickW—
EF025890COP at 7/35°C according to EN 14511numeric——
EF010933COPd at Tj=+7°Cnumeric——
EF009364Suitable for heater CVlogical——
EF002203Max. permitted liquid cable lengthnumericm—
EF021349Room temperature controllogical——
EF000462Type of regulationalphanumeric—
  • EV021747 On/Off
  • EV011491 Weather-dependent control
  • EV000358 External
EF026384Kind of optimizationalphanumeric—
  • EV022103 OpenTherm
  • EV023103 Room thermostat
  • EV011603 Space sensor
EF009424External controller requiredlogical——
EF021195Suitable for hot tap waterlogical——
EF009440Suitable for active coolinglogical——
EF025848Cooling integratedlogical——
EF009441Cooling performance min/max at 35/18° according to EN 14511rangekW—
EF009442Cooling performance min/max at 35/7° according to EN 14511rangekW—
EF023919Suitable for swimming pool water heatinglogical——
EF020666Swimming pool controlslogical——
EF009386Regulation for central heating boiler controllogical——
EF009387Regulation for buffer tank controllogical——
EF024815With electric heating elementlogical——
EF025850Power electric heating elementrangekW—
EF009388Heating power electrical element adjustable in stageslogical——
EF026387Modulating compressorlogical——
EF009426Modulation percentagerange%—
EF024945Type of refrigerantalphanumeric—
  • EV022300 R-134a
  • EV022304 R-407C
  • EV022305 R-410A
  • EV000154 Other
EF002269Filling quantity refrigerantnumerickg—
EF003625Connection voltagenumericV—
EF024947Fuse (slow)numericA—
EF000008Widthnumericmm—
EF000040Heightnumericmm—
EF000049Depthnumericmm—
EF000167Weightnumerickg—
EF025880Sound performance level (according to EN12102 at 0/35°C)numericdB(A)—
EF026125Sound pressure level acc. EN-ISO 11203 at 0/35°C at 1 m. distancenumericdB—
EF009427External pressure system pump available at nominal flownumericbar—
EF006333Max. heating water temperaturenumeric°C—
EF021120Max. pressure of hot tap waternumericbar—
EF025884Nominal volume flow rate output systemnumericl/s—
EF025885Max. operating pressure output systemnumericbar—
EF009291Outer diameter tap water pipealphanumeric—
  • EV006932 1 inch external
  • EV006927 1 1/4 inch external
  • EV020127 22 mm
  • EV020129 28 mm
EF009293Outer pipe diameter connection output systemalphanumeric—
  • EV006932 1 inch external
  • EV006927 1 1/4 inch external
  • EV020127 22 mm
  • EV020129 28 mm
EF005474Degree of protection (IP)alphanumeric—
  • EV006404 IP00
  • EV006606 IP10
  • EV006607 IP12
  • EV006405 IP20
  • EV006608 IP22
  • EV006408 IP24
  • EV010200 IP25
  • EV006409 IP2X
  • EV006410 IP30
  • EV006411 IP31
  • EV006412 IP32
  • EV006609 IP33
  • EV006413 IP34
  • EV006414 IP3X
  • EV006415 IP40
  • EV006416 IP41
  • EV006417 IP42
  • EV006610 IP43
  • EV006418 IP44
  • EV006611 IP45
  • EV006612 IP50
  • EV006613 IP52
  • EV006614 IP53
  • EV006419 IP54
  • EV006420 IP55
  • EV006615 IP56
  • EV006616 IP57
  • EV006617 IP58
  • EV006618 IP64
  • EV006421 IP65
  • EV006422 IP66
  • EV006423 IP67
  • EV006619 IP68
  • EV006620 IPX0
  • EV009850 IPX1
  • EV009851 IPX3
  • EV006621 IPX4
  • EV009852 IPX5
  • EV006622 IPX7
  • EV000154 Other
EF003361Remote operation possiblelogical——
EF008435Data transfer via USBlogical——
EF026126Data transfer via internetlogical——
EF009428Data transfer via bus connectionlogical——
EF009434Type of pump (system pump)alphanumeric—
  • EV005866 Standard
  • EV010834 Energy saving
EF009435Type voltage pump (system pump)alphanumeric—
  • EV022427 Direct current
  • EV000385 Alternating current
EF009436Speed control pump (system pump)alphanumeric—
  • EV000494 None
  • EV004710 Inbuilt
  • EV000358 External
EF009437Type of speed control (system pump)alphanumeric—
  • EV020201 Stepped
  • EV000552 Continuously variable
  • EV011606 Automatically controlled on dT
EF026130Connection and control multiple output systems possiblelogical——
EF009438Sofstarter built-inlogical——
EF009439Limitation max. electric power consumptionnumericA—
EF010784SEER low temperature application (35°C) at average conditionsnumeric%—
EF010785SEER low temperature application (35°C) at colder conditionsnumeric%—
EF010786SEER low temperature application (35°C) at warmer conditionsnumeric%—
EF010787SEER middle temperature application (55°C) at average conditionsnumeric%—
EF010788SEER middle temperature application (55°C) at colder conditionsnumeric%—
EF010789SEER middle temperature application (55°C) at warmer conditionsnumeric%—
EF010599Water heating energy efficiency (Nwh)numeric%—
EF010777Capacity profilealphanumeric—
  • EV011136 XXXS
  • EV021036 XXS
  • EV010494 XS
  • EV002065 S
  • EV003295 M
  • EV000141 L
  • EV003296 XL
  • EV003297 XXL
EF010855Energy efficiency class room heatingalphanumeric—
  • EV010818 A+++
  • EV007056 A++
  • EV007055 A+
  • EV000896 A
  • EV000074 B
  • EV000084 C
  • EV000413 D
  • EV000647 E
  • EV000334 F
  • EV004701 G
EF010856Energy efficiency class water heatingalphanumeric—
  • EV010818 A+++
  • EV007056 A++
  • EV007055 A+
  • EV000896 A
  • EV000074 B
  • EV000084 C
  • EV000413 D
  • EV000647 E
  • EV000334 F
  • EV004701 G

Requirement levels are not part of this standard and are not shown.