etim 8.0 · Class
EC012035Heat pump (air/water) split type
Definition not reported by the standard.
Synonyms: Heat pump, Heat pump (air/water) split type, Heat pump (water/water), Heating heat pump, Pump
- Stable identifier
etim:EC012035- Permalink
- /classifications/etim/8.0/EC012035
- Class revision in the standard
- 3
Properties (73)
| Code | Label (EN) | Type | Unit | Allowed values |
|---|---|---|---|---|
| EF000010 | Model | alphanumeric | — |
|
| EF025889 | Heating capacity at 7/35 °C according to EN 14511 | numeric | kW | — |
| EF025890 | COP at 7/35 °C according to EN 14511 | numeric | — | — |
| EF010933 | COPd at Tj = +7 °C | numeric | — | — |
| EF009364 | Suitable for additional heating central heating | logical | — | — |
| EF024974 | Max. pipe length | numeric | m | — |
| EF021349 | Room temperature control | logical | — | — |
| EF000462 | Type of regulation | alphanumeric | — |
|
| EF026384 | Kind of optimization | alphanumeric | — |
|
| EF009424 | External controller required | logical | — | — |
| EF021195 | Suitable for hot tap water | logical | — | — |
| EF009440 | Suitable for active cooling | logical | — | — |
| EF025848 | Cooling integrated | logical | — | — |
| EF009441 | Cooling performance at 35/18 °C according to EN 14511 | range | kW | — |
| EF009442 | Cooling performance at 35/7 °C according to EN 14511 | range | kW | — |
| EF023919 | Suitable for swimming pool water heating | logical | — | — |
| EF020666 | Swimming pool controls | logical | — | — |
| EF009386 | Regulation for central heating boiler control | logical | — | — |
| EF009387 | Regulation for buffer tank control | logical | — | — |
| EF024815 | With electric heating element | logical | — | — |
| EF025850 | Power electric heating element | range | kW | — |
| EF009388 | Heating power electrical element adjustable in stages | logical | — | — |
| EF026387 | Modulating compressor | logical | — | — |
| EF009426 | Modulation percentage | range | % | — |
| EF024945 | Type of refrigerant | alphanumeric | — |
|
| EF002269 | Filling quantity refrigerant | numeric | kg | — |
| EF024967 | Nominal diameter fluid pipe | alphanumeric | — |
|
| EF020136 | Nominal diameter suction pipe | alphanumeric | — |
|
| EF003625 | Connection voltage | numeric | V | — |
| EF024947 | Fuse (slow) | numeric | A | — |
| EF000864 | Width indoor unit | numeric | mm | — |
| EF000865 | Height indoor unit | numeric | mm | — |
| EF000866 | Depth indoor unit | numeric | mm | — |
| EF000867 | Weight indoor unit | numeric | kg | — |
| EF000869 | Width outdoor unit | numeric | mm | — |
| EF000868 | Height outdoor unit | numeric | mm | — |
| EF000870 | Depth outdoor unit | numeric | mm | — |
| EF000871 | Weight outdoor unit | numeric | kg | — |
| EF015727 | Sound performance level indoor unit (according to EN12102 at 0/35 °C) | numeric | dB(A) | — |
| EF015728 | Sound performance level outdoor unit (according to EN12102 at 0/35 °C) | numeric | dB(A) | — |
| EF015837 | Sound pressure level indoor unit according to EN12102 at 0/35 °C /1m distance | numeric | dB | — |
| EF015838 | Sound pressure level outdoor unit according to EN12102 at 0/35 °C /1m distance | numeric | dB | — |
| EF009427 | External pressure system pump available at nominal flow | numeric | bar | — |
| EF006333 | Max. heating water supply temperature | numeric | °C | — |
| EF003361 | Remote operation possible | logical | — | — |
| EF021120 | Max. pressure of hot tap water | numeric | bar | — |
| EF025884 | Nominal volume flow rate output system | numeric | l/s | — |
| EF008435 | Data transfer via USB | logical | — | — |
| EF025885 | Max. operating pressure output system | numeric | bar | — |
| EF026126 | Data transfer via internet | logical | — | — |
| EF009291 | Outer pipe diameter tap water | alphanumeric | — |
|
| EF009428 | Data transfer via bus connection | logical | — | — |
| EF009434 | Type of pump (system pump) | alphanumeric | — |
|
| EF020863 | Nominal diameter central heating | alphanumeric | — |
|
| EF025887 | Outer pipe diameter connection output system | numeric | mm | — |
| EF009435 | Type voltage pump (system pump) | alphanumeric | — |
|
| EF009436 | Speed control pump (system pump) | alphanumeric | — |
|
| EF009437 | Type of speed control (system pump) | alphanumeric | — |
|
| EF026130 | Connection and control multiple output systems possible | logical | — | — |
| EF009438 | Sofstarter built-in | logical | — | — |
| EF009439 | Limitation max. electric power consumption | numeric | A | — |
| EF010784 | SEER low temperature application (35 °C) at average conditions | numeric | % | — |
| EF010785 | SEER low temperature application (35 °C) at colder conditions | numeric | % | — |
| EF010786 | SEER low temperature application (35 °C) at warmer conditions | numeric | % | — |
| EF010787 | SEER middle temperature application (55 °C) at average conditions | numeric | % | — |
| EF010788 | SEER middle temperature application (55 °C) at colder conditions | numeric | % | — |
| EF010789 | SEER middle temperature application (55 °C) at warmer conditions | numeric | % | — |
| EF010599 | Water heating energy efficiency (Nwh) | numeric | % | — |
| EF010777 | Capacity profile | alphanumeric | — |
|
| EF010855 | Energy efficiency class room heating | alphanumeric | — |
|
| EF010856 | Energy efficiency class water heating | alphanumeric | — |
|
| EF015729 | Degree of protection (IP) interior unit | alphanumeric | — |
|
| EF015730 | Degree of protection (IP) outdoor unit | alphanumeric | — |
|
Requirement levels are not part of this standard and are not shown.
Change history
Per-class history is not reported. Compare releases to see what changed between versions.