etim 7.0 · Class
EC010595Solar heater tank with integrated CH
Definition not reported by the standard.
Synonyms: Solar heater tank with integrated CH
- Stable identifier
etim:EC010595- Permalink
- /classifications/etim/7.0/EC010595
- Class revision in the standard
- 5
Properties (90)
| Code | Label (EN) | Type | Unit | Allowed values |
|---|---|---|---|---|
| EF020003 | Heat exchanger material | alphanumeric | — |
|
| EF005870 | Closed version | logical | — | — |
| EF021412 | Open model | logical | — | — |
| EF020447 | Nominal power, 80-60°C | numeric | kW | — |
| EF023877 | Nominal power, 50-30°C | numeric | kW | — |
| EF020087 | Nominal load upper value | numeric | kW | — |
| EF020086 | Nominal load lower value | numeric | kW | — |
| EF020006 | Heating capacity adjustable | logical | — | — |
| EF023845 | Pilot light | logical | — | — |
| EF021059 | Suitable for natural gas | logical | — | — |
| EF021467 | Suitable for natural gas | logical | — | — |
| EF005844 | Suitable for propane | logical | — | — |
| EF023880 | Suitable for propane | logical | — | — |
| EF021137 | Suitable for butane | logical | — | — |
| EF023881 | Suitable for butane | logical | — | — |
| EF022160 | Suitable for methane | logical | — | — |
| EF023882 | Suitable for methane | logical | — | — |
| EF025001 | Conversion kit required | logical | — | — |
| EF023847 | Control signal on/off | logical | — | — |
| EF023848 | Control signal high/low | logical | — | — |
| EF023850 | Control signal OpenTherm | logical | — | — |
| EF023849 | Control signal 0-10 V | logical | — | — |
| EF022183 | Burner controller high/low | logical | — | — |
| EF022184 | Burner controller, modulating | logical | — | — |
| EF020448 | Max. supply temperature (operating temperature) | numeric | °C | — |
| EF020089 | Min. return temperature | numeric | °C | — |
| EF023885 | Max. allowable operating pressure | numeric | bar | — |
| EF020088 | Min. operating pressure | numeric | bar | — |
| EF022702 | With HE gas quality mark | logical | — | — |
| EF021060 | VR gas quality mark | logical | — | — |
| EF020071 | Gas quality mark VR/SV | logical | — | — |
| EF020072 | Gas quality mark NZ | logical | — | — |
| EF022931 | Efficiency | numeric | %/100% | — |
| EF020073 | CW label | numeric | — | — |
| EF020090 | Max. gas pre-pressure | numeric | mbar | — |
| EF020541 | Min. gas pre-pressure | numeric | mbar | — |
| EF020098 | Water-side resistance at dT 20°C | numeric | kPa | — |
| EF023846 | Second return connection | logical | — | — |
| EF020092 | Hot tap water capacity at 60°C | numeric | l/min | — |
| EF020034 | Tap threshold | numeric | l/min | — |
| EF023890 | Hot tap water supply | numeric | l | — |
| EF000104 | Supply voltage | numeric | V | — |
| EF002225 | With filling- and draining valve | logical | — | — |
| EF021142 | With pump circuit | logical | — | — |
| EF002223 | With pressure gauge | logical | — | — |
| EF021143 | With weather-dependent controller | logical | — | — |
| EF021114 | With pressure expansion vessel | logical | — | — |
| EF020451 | Built-in pressure relief valve | logical | — | — |
| EF000040 | Height | numeric | mm | — |
| EF000008 | Width | numeric | mm | — |
| EF000049 | Depth | numeric | mm | — |
| EF002286 | Connection feed | alphanumeric | — |
|
| EF023886 | Nominal inner diameter of supply | alphanumeric | — |
|
| EF023923 | Feed thread size | alphanumeric | — |
|
| EF020469 | Outer pipe diameter of feed | numeric | mm | — |
| EF002287 | Connection return | alphanumeric | — |
|
| EF023887 | Nominal inner diameter of return | alphanumeric | — |
|
| EF023924 | Return thread size | alphanumeric | — |
|
| EF020475 | Outer pipe diameter of return | numeric | mm | — |
| EF020481 | Connection, fuel | alphanumeric | — |
|
| EF023888 | Nominal inner diameter for fuel | alphanumeric | — |
|
| EF023925 | Fuel thread size | alphanumeric | — |
|
| EF020482 | Outer pipe diameter, fuel | numeric | mm | — |
| EF020488 | Connection, air supply | alphanumeric | — |
|
| EF020489 | Nominal duct width, air supply | numeric | mm | — |
| EF020494 | Connection, flue | alphanumeric | — |
|
| EF021654 | Nominal duct diameter, flue | numeric | mm | — |
| EF021386 | Cold tap water connection | alphanumeric | — |
|
| EF020013 | Nominal inner diameter, cold tap water | alphanumeric | — |
|
| EF022399 | Thread size, cold tap water | alphanumeric | — |
|
| EF020499 | External cold tap water tube diameter | numeric | mm | — |
| EF021387 | Hot tap water connection | alphanumeric | — |
|
| EF010896 | Nominal internal diameter hot tap water | alphanumeric | — |
|
| EF023926 | Hot tap water thread size | alphanumeric | — |
|
| EF020504 | Outer pipe diameter, hot tap water | numeric | mm | — |
| EF020510 | Condensate connection | alphanumeric | — |
|
| EF020511 | Outer pipe diameter, condensate | numeric | mm | — |
| EF002153 | Material boiler tank | alphanumeric | — |
|
| EF021144 | Surface protection of boiler tank | alphanumeric | — |
|
| EF023942 | Tap water boiler volume | numeric | l | — |
| EF010596 | Standing loss (S) | numeric | W | — |
| EF023944 | Tap water in stock | logical | — | — |
| EF023943 | Collector water in stock | logical | — | — |
| EF023945 | With integrated return vessel | logical | — | — |
| EF023933 | EPN coefficient | numeric | — | — |
| EF022504 | Assembled | logical | — | — |
| EF010597 | Seasonal space heating energy efficiency (Ns) | numeric | % | — |
| EF010779 | Pump power consumption (solpump) | numeric | W | — |
| EF010780 | Pump power consumption standby (solstandbypump) | numeric | W | — |
| EF000758 | Energy efficiency class | alphanumeric | — |
|
Requirement levels are not part of this standard and are not shown.
Change history
Per-class history is not reported. Compare releases to see what changed between versions.