etim 8.0 · Class
EC011395Air heater, directly fired, suspended
Definition not reported by the standard.
Synonyms: Air heater, directly fired, suspended
- Stable identifier
etim:EC011395- Permalink
- /classifications/etim/8.0/EC011395
- Class revision in the standard
- 3
Properties (56)
| Code | Label (EN) | Type | Unit | Allowed values |
|---|---|---|---|---|
| EF020003 | Material heat exchanger | alphanumeric | — |
|
| EF001257 | Material quality | alphanumeric | — |
|
| EF005870 | Closed version | logical | — | — |
| EF023876 | Operation as open model (air supply) possible | logical | — | — |
| EF000169 | Nominal power | numeric | kW | — |
| EF020087 | Nominal load upper value | numeric | kW | — |
| EF020093 | Fuel type | alphanumeric | — |
|
| EF020086 | Nominal load lower value | numeric | kW | — |
| EF022183 | Burner controller high/low | logical | — | — |
| EF022184 | Burner controller, modulating | logical | — | — |
| EF022299 | Burner controller, pulsating | logical | — | — |
| EF023847 | Control signal on/off | logical | — | — |
| EF023849 | Control signal 0-10 V | logical | — | — |
| EF023850 | Control signal OpenTherm | logical | — | — |
| EF022303 | Pilot light with piezo ignition | logical | — | — |
| EF022302 | Fan type | alphanumeric | — |
|
| EF022300 | dT heating air | range | K | — |
| EF006340 | Air volume | range | m³/h | — |
| EF013919 | Max. throw horizontal | numeric | m | — |
| EF013920 | Max. throw vertical | numeric | m | — |
| EF022304 | Euroair Quality label | logical | — | — |
| EF022702 | Gas quality mark HE | logical | — | — |
| EF020090 | Max. gas pre-pressure | numeric | mbar | — |
| EF020541 | Min. gas pre-pressure | numeric | mbar | — |
| EF013929 | Gas consumption high-calorific natural gas (G20) | numeric | m³/h | — |
| EF013923 | Gas consumption low-calorific natural gas (G25) | numeric | m³/h | — |
| EF013924 | Gas consumption propane (G31) | numeric | kg/h | — |
| EF022931 | Efficiency | numeric | % | — |
| EF000104 | Supply voltage | numeric | V | — |
| EF000001 | Nominal current | numeric | A | — |
| EF023037 | Max. electric power input | numeric | W | — |
| EF010912 | Supplementary electricity consumption in standby-mode (Psb) | numeric | W | — |
| EF000034 | Frequency | numeric | Hz | — |
| EF005474 | Degree of protection (IP) | alphanumeric | — |
|
| EF000040 | Height | numeric | mm | — |
| EF000008 | Width | numeric | mm | — |
| EF000049 | Depth | numeric | mm | — |
| EF022313 | Connection, outlet side | alphanumeric | — |
|
| EF022305 | Connection side duct height | numeric | mm | — |
| EF022306 | Connection side duct width | numeric | mm | — |
| EF022195 | Connection suction side | alphanumeric | — |
|
| EF022314 | Exhaust side duct height | numeric | mm | — |
| EF022315 | Exhaust sides duct width | numeric | mm | — |
| EF020481 | Connection, fuel | alphanumeric | — |
|
| EF023888 | Nominal diameter fuel | alphanumeric | — |
|
| EF020482 | Outer pipe diameter fuel | numeric | mm | — |
| EF022316 | Outer pipe diameter combustion air | numeric | mm | — |
| EF020494 | Connection, flue | alphanumeric | — |
|
| EF021654 | Nominal duct diameter, flue | numeric | mm | — |
| EF020510 | Condensate connection | alphanumeric | — |
|
| EF020511 | Outer pipe diameter condensate | numeric | mm | — |
| EF010597 | Seasonal space heating energy efficiency (Ns) | numeric | % | — |
| EF013930 | Max. sound level (at a distance of 4 metres) | numeric | dB(A) | — |
| EF013921 | Min. mounting height (horizontal air distribution) | numeric | m | — |
| EF013922 | Min. mounting height (vertical air distribution) | numeric | m | — |
| EF000167 | Weight | numeric | kg | — |
Requirement levels are not part of this standard and are not shown.
Change history
Per-class history is not reported. Compare releases to see what changed between versions.