Skip to content
Sign in

ETIM technical information model, English master (unofficial mirror)

License:ODC-By-1.0Community · the product.cloud project (unofficial mirror)Updated · latest release 10.0
  • Validated
  • Community maintained
About access and trust
Open
Immediately usable under the displayed license. Access is separate from the license.
License
ODC-By-1.0 governs use, including for open repositories.
You
No entitlement needed: the content is open.
Validated
Required rulepack checks passed for the named revision.
Community maintained
Maintained by contributors, not the named product authority.
Release 5.0 — pinned
Follow0 Use repository
Hierarchy

etim 5.0 · Class

EC001097Switch actuator for bus system

Definition not reported by the standard.

Synonyms: Adapter plug, Bus system, EIB, Output module, Switch actuator for bus system

Stable identifier
etim:EC001097
Class revision in the standard
5

Properties (22)

Properties of EC001097 in English with German for comparison
CodeLabel (EN)Label (DE)TypeUnitAllowed values
EF001499Bus system KNXBus system KNXen fallback: no German translationlogical——
EF008855Bus system KNX radioBus system KNX radioen fallback: no German translationlogical——
EF001500Bus system radio frequentBus system radio frequenten fallback: no German translationlogical——
EF003831Bus system LONBus system LONen fallback: no German translationlogical——
EF001501Bus system PowernetBus system Powerneten fallback: no German translationlogical——
EF003811Other bus systemsOther bus systemsen fallback: no German translationalphanumeric—
  • EV006376 Dupline
  • EV006402 IHC
  • EV006467 PHC
  • EV008871 Nikobus
  • EV010126 Tebis TX
  • EV000154 Other
  • EV000494 None
EF000003Mounting methodMounting methoden fallback: no German translationalphanumeric—
  • EV000383 Flush mounted (plaster)
  • EV000384 Surface mounted (plaster)
  • EV006471 DRA
  • EV003187 Wall duct
  • EV009726 Built-in installation
  • EV000154 Other
EF002950Width in number of modular spacingsWidth in number of modular spacingsen fallback: no German translationnumeric——
EF003914Local operation/hand operationLocal operation/hand operationen fallback: no German translationlogical——
EF005950With LED indicationWith LED indicationen fallback: no German translationlogical——
EF003817Number of binary inputsNumber of binary inputsen fallback: no German translationnumeric——
EF003648Max. switching currentMax. switching currenten fallback: no German translationnumericA—
EF001503Max. switching powerMax. switching poweren fallback: no German translationnumericW—
EF003832C-loadC-loaden fallback: no German translationlogical——
EF001739Max. number of switching contactsMax. number of switching contactsen fallback: no German translationnumeric——
EF000426Output powerOutput poweren fallback: no German translationnumericW—
EF000227Rated currentRated currenten fallback: no German translationnumericA—
EF001435Rated operating voltageRated operating voltageen fallback: no German translationrangeV—
EF003905Different phases connectableDifferent phases connectableen fallback: no German translationlogical——
EF001504Bus connection includedBus connection includeden fallback: no German translationlogical——
EF006738Modular expandabilityModular expandabilityen fallback: no German translationlogical——
EF005474Degree of protection (IP)Degree of protection (IP)en fallback: no German translationalphanumeric—
  • EV006404 IP00
  • EV006405 IP20
  • EV006406 IP21
  • EV006608 IP22
  • EV006407 IP23
  • EV006408 IP24
  • EV006409 IP2X
  • EV006410 IP30
  • EV006411 IP31
  • EV006412 IP32
  • EV006413 IP34
  • EV006414 IP3X
  • EV006415 IP40
  • EV006416 IP41
  • EV006417 IP42
  • EV006418 IP44
  • EV006419 IP54
  • EV006420 IP55
  • EV006421 IP65
  • EV006422 IP66
  • EV006423 IP67
  • EV000154 Other

Requirement levels are not part of this standard and are not shown.

Change history

Per-class history is not reported. Compare releases to see what changed between versions.

    Data: ETIM International · ODC-By-1.0