Hierarchy

etim 5.0 · Class

EC001582Movement sensor for bus system

Definition not reported by the standard.

Synonyms: Movement sensor, Movement sensor complete, Movement sensor for bus system, Presence detector

Stable identifier
etim:EC001582
Class revision in the standard
5

Properties (35)

Properties of EC001582 in English with German for comparison
CodeLabel (EN)Label (DE)TypeUnitAllowed values
EF001499Bus system KNXBus system KNXen fallback: no German translationlogical——
EF008855Bus system KNX radioBus system KNX radioen fallback: no German translationlogical——
EF001500Bus system radio frequentBus system radio frequenten fallback: no German translationlogical——
EF003831Bus system LONBus system LONen fallback: no German translationlogical——
EF001501Bus system PowernetBus system Powerneten fallback: no German translationlogical——
EF003811Other bus systemsOther bus systemsen fallback: no German translationalphanumeric—
  • EV006376 Dupline
  • EV006402 IHC
  • EV006467 PHC
  • EV008871 Nikobus
  • EV010126 Tebis TX
  • EV000154 Other
  • EV000494 None
EF000010ModelModelen fallback: no German translationalphanumeric—
  • EV004048 Movement sensor
  • EV004050 Presence detector
  • EV000154 Other
EF000003Mounting methodMounting methoden fallback: no German translationalphanumeric—
  • EV000383 Flush mounted (plaster)
  • EV000384 Surface mounted (plaster)
  • EV006471 DRA
  • EV003187 Wall duct
  • EV000154 Other
EF002169MaterialMaterialen fallback: no German translationalphanumeric—
  • EV000139 Plastic
  • EV000914 Metal
  • EV000219 Glass
  • EV000131 Wood
  • EV003673 Stone
  • EV000154 Other
EF001257Material qualityMaterial qualityen fallback: no German translationalphanumeric—
  • EV001304 Duroplast
  • EV000403 Thermoplastic
  • EV000072 Aluminium
  • EV000294 Stainless steel
  • EV000138 Copper
  • EV007710 Slate
  • EV000154 Other
EF000139Surface treatmentSurface treatmenten fallback: no German translationalphanumeric—
  • EV000112 Anodised
  • EV010983 Decor
  • EV006393 Galvanized
  • EV000113 Varnished
  • EV005968 Metallic
  • EV009951 Nano coated
  • EV007971 Sand-cast
  • EV000154 Other
  • EV006034 Untreated
EF006569Type of surfaceType of surfaceen fallback: no German translationalphanumeric—
  • EV006395 Brilliant
  • EV000146 Matt
  • EV008336 Not applicable
EF000007ColourColouren fallback: no German translationalphanumeric—
  • EV000072 Aluminium
  • EV000309 Anthracite
  • EV000279 Beige
  • EV000080 Blue
  • EV008030 Cyan (blue-green)
  • EV000083 Brown
  • EV000082 Bronze
  • EV000291 Chrome
  • EV000294 Stainless steel
  • EV008893 Cream white/electro white
  • EV000234 Yellow
  • EV000119 Gold
  • EV000270 Grey
  • EV000235 Green
  • EV000131 Wood
  • EV000149 Brass
  • EV000236 Orange
  • EV000290 Platinum
  • EV000233 Red
  • EV000206 Black
  • EV000205 Silver
  • EV000300 Titanium
  • EV000202 White
  • EV000256 Natural colour
  • EV000154 Other
EF003882RAL-number (akin)RAL-number (akin)en fallback: no German translationnumeric——
EF006243TransparentTransparenten fallback: no German translationlogical——
EF001504Bus connection includedBus connection includeden fallback: no German translationlogical——
EF003876Substation inputSubstation inputen fallback: no German translationlogical——
EF000147Creep-under protectionCreep-under protectionen fallback: no German translationlogical——
EF006740Slide switchSlide switchen fallback: no German translationlogical——
EF006311Animal zoneAnimal zoneen fallback: no German translationlogical——
EF001098Staircase monitoringStaircase monitoringen fallback: no German translationlogical——
EF007575Response value luminosity adjustableResponse value luminosity adjustableen fallback: no German translationlogical——
EF003898Teach-function for response value luminosityTeach-function for response value luminosityen fallback: no German translationlogical——
EF007667Switch-off delay self-learningSwitch-off delay self-learningen fallback: no German translationlogical——
EF008011Optimum mounting heightOptimum mounting heighten fallback: no German translationnumericm—
EF001323Max. transmission range sidewaysMax. transmission range sidewaysen fallback: no German translationnumericm—
EF001322Max. transmission range frontallyMax. transmission range frontallyen fallback: no German translationnumericm—
EF003843Diameter detection range on floorDiameter detection range on flooren fallback: no German translationnumericm—
EF006581Detection angle verticalDetection angle verticalen fallback: no German translationrange°—
EF006582Detection angle horizontalDetection angle horizontalen fallback: no German translationrange°—
EF000259Number of channelsNumber of channelsen fallback: no German translationnumeric——
EF003817Number of binary inputsNumber of binary inputsen fallback: no German translationnumeric——
EF001313Switching powerSwitching poweren fallback: no German translationnumericW—
EF006589Min. switch-on timeMin. switch-on timeen fallback: no German translationnumerics—
EF006590Max. duty cycleMax. duty cycleen fallback: no German translationnumericmin—