Hierarchy

etim 5.0 · Class

EC000688Binary input for bus system

Definition not reported by the standard.

Synonyms: Binary input, Binary input for bus system, Bus system, EIB, Nikobus, Sensor

Stable identifier
etim:EC000688
Class revision in the standard
5

Properties (16)

Properties of EC000688 in English with German for comparison
CodeLabel (EN)Label (DE)TypeUnitAllowed values
EF001499Bus system KNXBus system KNXen fallback: no German translationlogical——
EF008855Bus system KNX radioBus system KNX radioen fallback: no German translationlogical——
EF001500Bus system radio frequentBus system radio frequenten fallback: no German translationlogical——
EF003831Bus system LONBus system LONen fallback: no German translationlogical——
EF001501Bus system PowernetBus system Powerneten fallback: no German translationlogical——
EF003811Other bus systemsOther bus systemsen fallback: no German translationalphanumeric—
  • EV006376 Dupline
  • EV006402 IHC
  • EV006467 PHC
  • EV008871 Nikobus
  • EV010126 Tebis TX
  • EV000154 Other
  • EV000494 None
EF000003Mounting methodMounting methoden fallback: no German translationalphanumeric—
  • EV000383 Flush mounted (plaster)
  • EV000384 Surface mounted (plaster)
  • EV006471 DRA
  • EV003187 Wall duct
  • EV009726 Built-in installation
  • EV000154 Other
EF002950Width in number of modular spacingsWidth in number of modular spacingsen fallback: no German translationnumeric——
EF001504Bus connection includedBus connection includeden fallback: no German translationlogical——
EF003866LED controllingLED controllingen fallback: no German translationlogical——
EF005950With LED indicationWith LED indicationen fallback: no German translationlogical——
EF000318Number of inputsNumber of inputsen fallback: no German translationnumeric——
EF003840Primary voltagePrimary voltageen fallback: no German translationrangeV—
EF003809External signal voltage necessaryExternal signal voltage necessaryen fallback: no German translationlogical——
EF005474Degree of protection (IP)Degree of protection (IP)en fallback: no German translationalphanumeric—
  • EV006404 IP00
  • EV006405 IP20
  • EV006406 IP21
  • EV006608 IP22
  • EV006407 IP23
  • EV006408 IP24
  • EV006409 IP2X
  • EV006410 IP30
  • EV006411 IP31
  • EV006412 IP32
  • EV006413 IP34
  • EV006414 IP3X
  • EV006415 IP40
  • EV006416 IP41
  • EV006417 IP42
  • EV006418 IP44
  • EV006419 IP54
  • EV006420 IP55
  • EV006421 IP65
  • EV006422 IP66
  • EV006423 IP67
  • EV000154 Other
EF001425Type of input voltageType of input voltageen fallback: no German translationalphanumeric—
  • EV000460 AC
  • EV000461 DC
  • EV000509 AC/DC
  • EV011001 Pulsed

Requirement levels are not part of this standard and are not shown.