etim 9.0 · Class
EC010559Air treatment cabinet
Definition not reported by the standard.
Synonyms: Air handler, Air treatment cabinet, Air treatment cabinet, inside, Air treatment cabinet, outside
- Stable identifier
etim:EC010559- Permalink
- /classifications/etim/9.0/EC010559
- Parent
- EG015170 Air treatment
- Class revision in the standard
- 3
Properties (50)
| Code | Label (EN) | Type | Unit | Allowed values |
|---|---|---|---|---|
| EF024378 | Device emplacement | alphanumeric | — |
|
| EF001596 | Housing material | alphanumeric | — |
|
| EF024143 | Housing material quality | alphanumeric | — |
|
| EF024150 | Surface protection housing | alphanumeric | — |
|
| EF021889 | Air volume, unloaded | numeric | m³/h | — |
| EF014851 | Max. air volume at 50 Pa | numeric | m³/h | — |
| EF014959 | Max. air volume at 100 Pa | numeric | m³/h | — |
| EF014962 | Max. air volume at 250 Pa | numeric | m³/h | — |
| EF014965 | Max. air volume at 400 Pa | numeric | m³/h | — |
| EF013391 | Supply filter according to ISO 16890-1:2016 | alphanumeric | — |
|
| EF014694 | Efficiency supply filter according to ISO 16890-1:2016 | numeric | % | — |
| EF002205 | Heat recovery by | alphanumeric | — |
|
| EF022201 | With bypass | logical | — | — |
| EF015093 | Type of cooling coil | alphanumeric | — |
|
| EF015100 | Type of heating coil | alphanumeric | — |
|
| EF015091 | Change-over system | logical | — | — |
| EF015092 | With humidifier | logical | — | — |
| EF015161 | Type of humidifier | alphanumeric | — |
|
| EF015095 | Type of supply fan | alphanumeric | — |
|
| EF013390 | Exhaust filter according to ISO 16890-1:2016 | alphanumeric | — |
|
| EF013389 | Efficiency exhaust filter according to ISO 16890-1:2016 | numeric | % | — |
| EF015096 | Type of exhaust fan | alphanumeric | — |
|
| EF003625 | Connection voltage | numeric | V | — |
| EF000346 | Power consumption | numeric | kW | — |
| EF006233 | With thermal overload protection | logical | — | — |
| EF003701 | Electrical connection | alphanumeric | — |
|
| EF021894 | Suitable for electronic control | logical | — | — |
| EF022077 | Suitable for frequency control | logical | — | — |
| EF021895 | Suitable for transformer control | logical | — | — |
| EF022075 | Pole-reversible | logical | — | — |
| EF009424 | External controller required | logical | — | — |
| EF000616 | Frost protection circuit | logical | — | — |
| EF002735 | Type of motor | alphanumeric | — |
|
| EF020120 | Type of speed control | alphanumeric | — |
|
| EF012735 | Number of connections suction side | numeric | — | — |
| EF022195 | Connection suction side | alphanumeric | — |
|
| EF022198 | Nominal duct height of suction end | numeric | mm | — |
| EF022199 | Nominal duct width of suction end | numeric | mm | — |
| EF024510 | Nominal duct diameter, suction side | numeric | mm | — |
| EF022194 | Connection delivery side | alphanumeric | — |
|
| EF012734 | Number of connections delivery side | numeric | — | — |
| EF024513 | Nominal duct height, delivery side | numeric | mm | — |
| EF024512 | Nominal duct width, delivery side | numeric | mm | — |
| EF024511 | Nominal duct diameter, delivery side | numeric | mm | — |
| EF005474 | Degree of protection (IP) | alphanumeric | — |
|
| EF003996 | Explosion safety | alphanumeric | — |
|
| EF021897 | Max. air temperature | numeric | °C | — |
| EF000040 | Height | numeric | mm | — |
| EF000008 | Width | numeric | mm | — |
| EF001438 | Length | numeric | mm | — |
Requirement levels are not part of this standard and are not shown.
Change history
Per-class history is not reported. Compare releases to see what changed between versions.