Hierarchy

etim 10.0 · Class

EC010210Electronic urinal flusher

Definition not reported by the standard.

Synonyms: Electronic urinal flusher

Stable identifier
etim:EC010210
Class revision in the standard
8

Properties (30)

Properties of EC010210 in English
CodeLabel (EN)TypeUnitAllowed values
EF000010Modelalphanumeric—
  • EV000603 Wall built-in
  • EV009508 Wall surface mounted
  • EV000563 Ceiling built-in
  • EV000154 Other
EF002671Basic colouralphanumeric—
  • EV000291 Chrome
  • EV000294 Stainless steel
  • EV000202 White
  • EV000154 Other
EF022117Operating methodalphanumeric—
  • EV000423 Infrared
  • EV020662 Photocell
  • EV020660 Radar
  • EV017954 Siphon detection (calorimetry)
  • EV000154 Other
EF017414With control platelogical——
EF001469Type of power supplyalphanumeric—
  • EV000389 Battery
  • EV005514 Bus system
  • EV022580 Transformer
  • EV000154 Other
EF000278With transformerlogical——
EF003625Connection voltagenumericV—
EF022042Volume supply classalphanumeric—
  • EV000494 None
  • EV003530 Z
  • EV000896 A
  • EV002065 S
  • EV000074 B
  • EV000084 C
  • EV000413 D
EF016260Pre-pressurerangebar—
EF022129Max. through flow capacity (300 kPa)numericl/s—
EF022134Adjustable throughflow capacitylogical——
EF024920Sensor detection rangenumericmm—
EF016259Activation timeranges—
EF024921Automatic cycle flushinglogical——
EF024922Frequency of cycle flushingrangeh—
EF022130Programmable with remote controllogical——
EF022133With building management system connectionlogical——
EF022131With pre-flushinglogical——
EF025103With intermediate flushinglogical——
EF002286Connection supplyalphanumeric—
  • EV004442 Internal thread
  • EV004441 External thread
  • EV020287 Soldered end
  • EV020242 Compression ring
  • EV000154 Other
EF020785Connection size supplyalphanumeric—
  • EV020128 8 mm
  • EV005953 10 mm
  • EV020126 12 mm
  • EV020098 15 mm
  • EV003501 3/8 inch
  • EV004591 1/2 inch
  • EV003502 3/4 inch
  • EV000154 Other
EF020969Outgoing connectionalphanumeric—
  • EV004442 Internal thread
  • EV004441 External thread
  • EV003691 Pipe
  • EV020287 Soldered end
  • EV020242 Compression ring
  • EV000154 Other
EF020970Size of outgoing connectionalphanumeric—
  • EV020128 8 mm
  • EV005953 10 mm
  • EV020126 12 mm
  • EV020098 15 mm
  • EV006965 16 mm
  • EV020160 18 mm
  • EV002960 19 mm
  • EV003501 3/8 inch
  • EV004591 1/2 inch
  • EV003502 3/4 inch
  • EV000154 Other
EF005464Built-in depthrangemm—
EF005492Wall distancerangemm—
EF005454Heightrangemm—
EF020963Extension set availablelogical——
EF006755Suitable for degree of protection (IP)alphanumeric—
  • EV006418 IP44
  • EV006611 IP45
  • EV006621 IPX4
  • EV000154 Other
EF016731Sound class according to EN ISO 3822alphanumeric—
  • EV020647 Group I, <= 20 dB(A)
  • EV020648 Group II, <= 30 dB(A)
  • EV000494 None
EFNL0001KIWA certifiedlogical——

Requirement levels are not part of this standard and are not shown.

Change history

Per-class history is not reported. Compare releases to see what changed between versions.

    Data: ETIM International · ODC-By-1.0