etim 10.0 · Class
EC004892Transformer meter cabinet
Definition not reported by the standard.
Synonyms: Indirect meter cabinet, Load part, Meter cabinet, indirect measurement, Meter part, Transformer cabinet, Transformer meter cabinet
- Stable identifier
etim:EC004892- Permalink
- /classifications/etim/10.0/EC004892
- Class revision in the standard
- 1
Properties (58)
| Code | Label (EN) | Type | Unit | Allowed values |
|---|---|---|---|---|
| EF000010 | Model | alphanumeric | — |
|
| EF000227 | Rated current | numeric | A | — |
| EF018517 | Continuous current Inc | numeric | A | — |
| EF019321 | Nominal voltage (Un) | numeric | V | — |
| EF001366 | Rated insulation voltage Ui | numeric | V | — |
| EF001663 | Rated frequency | range | Hz | — |
| EF002564 | Surge current capacity | numeric | kA | — |
| EF007050 | Rated short-time withstand current lcw | numeric | kA | — |
| EF001444 | Conditioned rated short-circuit current Iq | numeric | kA | — |
| EF011980 | Rated impulse withstand voltage Uimp | numeric | kV | — |
| EF005387 | Power loss | numeric | W | — |
| EF000122 | Number of doors | numeric | — | — |
| EF000123 | Number of locks | numeric | — | — |
| EF004453 | Number of distributor rows | numeric | — | — |
| EF000261 | Number of fields | numeric | — | — |
| EF019322 | Number of meter panels, direct measurement | numeric | — | — |
| EF018690 | Number of indirect meters | numeric | — | — |
| EF018691 | Number of switching device panels | numeric | — | — |
| EF015654 | Termination point meter location | logical | — | — |
| EF000118 | With mounting plate | logical | — | — |
| EF005441 | Type of meter | alphanumeric | — |
|
| EF018928 | Meter equipped with push-in distribution terminal block | logical | — | — |
| EF018929 | Meter equipped with optical communication head | logical | — | — |
| EF018930 | Meter equipped with control cable duct | logical | — | — |
| EF018931 | With power supply connector | logical | — | — |
| EF019323 | With primary wiring | logical | — | — |
| EF018692 | With secondary wiring | logical | — | — |
| EF018706 | With metering transformer conversion board | logical | — | — |
| EF018707 | Suitable for metering transformer conversion board | logical | — | — |
| EF000003 | Mounting method | alphanumeric | — |
|
| EF005373 | Connection space, power side | alphanumeric | — |
|
| EF019484 | Number of poles busbar (connection space, power side) | alphanumeric | — |
|
| EF018932 | Disconnecting point, power side | alphanumeric | — |
|
| EF018933 | Disconnecting point, system side | alphanumeric | — |
|
| EF018696 | Voltage path fuse protection | alphanumeric | — |
|
| EF018969 | Type of control fuse | alphanumeric | — |
|
| EF018934 | Equipment of transformer compartment | alphanumeric | — |
|
| EF018935 | Equipment of additional transformer meter compartment | alphanumeric | — |
|
| EF019324 | Overvoltage protection | alphanumeric | — |
|
| EF004223 | System configuration | alphanumeric | — |
|
| EF000268 | Max. cross section connection cable | numeric | mm² | — |
| EF018515 | Max. cross section outgoing cable | numeric | mm² | — |
| EF018700 | Test terminal, number of poles | numeric | — | — |
| EF011885 | Suitable for outdoor installation | logical | — | — |
| EF005474 | Degree of protection (IP) | alphanumeric | — |
|
| EF004293 | Impact strength | alphanumeric | — |
|
| EF000004 | Protection class according to IEC 61140 | alphanumeric | — |
|
| EF006786 | Pollution degree | alphanumeric | — |
|
| EF018936 | Electromagnetic compatibility (EMC) | alphanumeric | — |
|
| EF018968 | Rated load factor RDF | numeric | — | — |
| EF002386 | Ambient temperature | range | °C | — |
| EF000007 | Colour | alphanumeric | — |
|
| EF000116 | RAL-number | numeric | — | — |
| EF000008 | Width | numeric | mm | — |
| EF000040 | Height | numeric | mm | — |
| EF000049 | Depth | numeric | mm | — |
| EFDE0001 | VDE tested | logical | — | — |
| EFDE0123 | Number of compartments for additional devices | numeric | — | — |
Requirement levels are not part of this standard and are not shown.
Change history
Per-class history is not reported. Compare releases to see what changed between versions.