Hierarchy

etim 10.0 · Class

EC004827Heat pump (air/air, monoblock) for heat recovery unit

Definition not reported by the standard.

Synonyms: Heat pump (air/air, monoblock) for heat recovery unit

Stable identifier
etim:EC004827
Class revision in the standard
2

Properties (23)

Properties of EC004827 in English
CodeLabel (EN)TypeUnitAllowed values
EF006340Air volumerangem³/h—
EF025889Heating capacity at 7/35 °C according to EN 14511numerickW—
EF025890COP at 7/35 °C according to EN 14511numeric——
EF023195Nominal duct diameterrangemm—
EF014953Connections outdoor air sidealphanumeric—
  • EV020338 Insert end
  • EV020339 Duct end
  • EV016409 Insert-/duct end
  • EV000154 Other
EF014954Connections residential sidealphanumeric—
  • EV020338 Insert end
  • EV020339 Duct end
  • EV016409 Insert-/duct end
  • EV000154 Other
EF017702House connectionalphanumeric—
  • EV004731 Left
  • EV004732 Right
EF009441Cooling performance at 35/18 °C according to EN 14511rangekW—
EF009442Cooling performance at 35/7 °C according to EN 14511rangekW—
EF026387Modulating compressorlogical——
EF009426Modulation percentagerange%—
EF023753With control panellogical——
EF012384Operation by applogical——
EF023037Max. electric power inputnumerickW—
EF005502Connection voltagerangeV—
EF003961Type of electric connectionalphanumeric—
  • EV021670 Connecting cable with plug with protective contact
  • EV021671 Perilex connecting cable
  • EV020300 Terminals
  • EV000154 Other
EF013833Refrigerant pre-chargenumerickg—
EF024945Type of refrigerantalphanumeric—
  • EV022298 R22
  • EV022299 R23
  • EV015317 R32
  • EV022300 R134a
  • EV022301 R401a
  • EV022302 R402a
  • EV022303 R404a
  • EV022304 R407c
  • EV022305 R410a
  • EV022306 R413a
  • EV022307 R417a
  • EV022308 R507
  • EV022510 R290
  • EV000154 Other
EF016979Global warming potential (GWP)numeric——
EF000040Heightnumericmm—
EF000008Widthnumericmm—
EF000049Depthnumericmm—
EF021436Make and type-basedlogical——

Requirement levels are not part of this standard and are not shown.