Skip to content
Sign in

ETIM technical information model, English master (unofficial mirror)

License:ODC-By-1.0Community · the product.cloud project (unofficial mirror)Updated · latest release 10.0
  • Validated
  • Community maintained
About access and trust
Open
Immediately usable under the displayed license. Access is separate from the license.
License
ODC-By-1.0 governs use, including for open repositories.
You
No entitlement needed: the content is open.
Validated
Required rulepack checks passed for the named revision.
Community maintained
Maintained by contributors, not the named product authority.
Latest on main — may changePin this view to commit c61267fcfe43
Follow0 Use repository
Hierarchy

etim 10.0 · Class

EC004823Medium voltage indoor vacuum contactor

Definition not reported by the standard.

Synonyms: Contactor medium voltage power distribution, Medium voltage contactor, Medium voltage indoor vacuum contactor, Medium voltage vacuum contactor, Vacuum contactor medium voltage

Stable identifier
etim:EC004823
Class revision in the standard
1

Properties (37)

Properties of EC004823 in English
CodeLabel (EN)TypeUnitAllowed values
EF017559Switchgear technologyalphanumeric—
  • EV013601 Air insulated
  • EV013600 Gas insulated
  • EV000154 Other
EF012271Rated power-frequency withstand voltagenumerickV—
EF011980Rated impulse withstand voltage UimpnumerickV—
EF005455Frequencyalphanumeric—
  • EV008013 50 Hz
  • EV008017 60 Hz
  • EV008015 50/60 Hz
EF000228Rated voltagenumerickV—
EF000227Rated currentnumericA—
EF007050Rated short-time withstand current lcwnumerickA—
EF017728Rated peak withstand currentnumerickA—
EF012627Short-circuit breaking capacity (Isccr)numerickA—
EF017670Rated capacitive current back-to-backnumericA—
EF017729Breaking capacity with fusesnumerickA—
EF017753Short-circuit breaking capacity according to class E1numerickA—
EF017754Breaking capacity with fuses according to class E2numerickA—
EF005900Auxiliary voltage (AC)rangeV—
EF005901Auxiliary voltage (DC)rangeV—
EF001374Number of normally open contacts as main contactnumeric——
EF001375Number of normally closed contacts as main contactnumeric——
EF018062Number of mechanical operation cycles electrically latchednumeric——
EF017758Number of mechanical operation cycles mechanically latchednumeric——
EF018031Electrical endurance cycles according to IEC 60947 AC3numeric——
EF017759Opening time electrically latchedrangems—
EF017760Opening time mechanically latchedrangems—
EF017761Closing timerangems—
EF001742Operating temperaturerange°C—
EF017762According to IEC 62271-106logical——
EF006559Pulse counterlogical——
EF018021With interface shaftlogical——
EF017764With mechanical latchlogical——
EF017765Mechanical latch supply voltage (AC)rangeV—
EF017766Mechanical latch supply voltage (DC)rangeV—
EF017767Chopping currentrangeA—
EF000008Widthnumericmm—
EF000040Heightnumericmm—
EF000049Depthnumericmm—
EFNA0005According to CSA C22.2logical——
EFNA0006According to UL 347 6th editionlogical——
EFNA0007According to UL 347 7th editionlogical——

Requirement levels are not part of this standard and are not shown.

Change history

Per-class history is not reported. Compare releases to see what changed between versions.

    Data: ETIM International · ODC-By-1.0