Hierarchy

etim 8.0 · Class

EC003520Cable termination for medium and high voltage cables

Definition not reported by the standard.

Synonyms: Cable termination, Cable termination for medium and high voltage cables

Stable identifier
etim:EC003520
Class revision in the standard
2

Properties (10)

Properties of EC003520 in English
CodeLabel (EN)TypeUnitAllowed values
EF025624Suitable for indoor uselogical——
EF003532Suitable for outdoor uselogical——
EF011700Rated voltage U0/U (Um)alphanumeric—
  • EV013709 0.6/1 (1.2) kV
  • EV013710 3.6/6 (7.2) kV
  • EV013711 3.8/6.6 (7.2) kV
  • EV013712 6/10 (12) kV
  • EV013713 6.35/11 (12) kV
  • EV013714 8.7/15 (17.5) kV
  • EV013715 12/20 (24) kV
  • EV013716 12.7/22 (24) kV
  • EV013717 18/30 (36) kV
  • EV013718 19/33 (36) kV
  • EV013719 20.8/36 (42) kV
  • EV013720 36/63 (72.5) kV
  • EV013721 40/69 (72.5) kV
  • EV013722 52/90 (100) kV
  • EV013723 64/110 (123) kV
  • EV013724 76/132 (145) kV
  • EV013725 87/150 (170) kV
  • EV013726 130/225 (245) kV
  • EV013727 160/275 (300) kV
  • EV013728 200/345 (362) kV
  • EV013729 230/400 (420) kV
  • EV013730 290/500 (550) kV
  • EV000154 Other
EF011754Type of cable terminationalphanumeric—
  • EV004268 Cold-shrink
  • EV004267 Heat-shrink
  • EV013731 Hybrid-shrink
EF002520Material insulating materialalphanumeric—
  • EV000139 Plastic
  • EV003699 Paper
  • EV000154 Other
EF001792Number of coresnumeric——
EF007468With protective conductorlogical——
EF011755With cable luglogical——
EF000275Shape of cable lugalphanumeric—
  • EV000415 Screw connection
  • EV004361 Press fit
  • EV000494 None
EF005124Nominal cross sectionrangemm²—

Requirement levels are not part of this standard and are not shown.

Change history

Per-class history is not reported. Compare releases to see what changed between versions.

    Data: ETIM International · ODC-By-1.0