EC003270Six-way control valve with electric servomotor
Definition not reported by the standard.
Synonyms: Divide valve, Mix control valve, Mixing valve, Pressure compensated control valve, Six way control valve, Six-way control valve, Six-way control valve with electric servomotor
- Stable identifier
etim:EC003270- Permalink
- /classifications/etim/9.0/EC003270
- Class revision in the standard
- 3
Properties (50)
| Code | Label (EN) | Type | Unit | Allowed values |
|---|---|---|---|---|
| EF001596 | Housing material | alphanumeric | — |
|
| EF000139 | Surface protection | alphanumeric | — |
|
| EF023191 | Nominal diameter | alphanumeric | — |
|
| EF022472 | Connections | alphanumeric | — |
|
| EF020007 | Article compression class | alphanumeric | — |
|
| EF000010 | Model | alphanumeric | — |
|
| EF002464 | Volume flow | range | l/s | — |
| EF001908 | Volume flow measurement | logical | — | — |
| EF001006 | Measurement principle | alphanumeric | — |
|
| EF020727 | Volume flow preset | alphanumeric | — |
|
| EF024113 | Max. pressure difference in opened position | numeric | kPa | — |
| EF023182 | Medium temperature (continuous) | range | °C | — |
| EF011078 | Kvs value 1 | numeric | — | — |
| EF011079 | Leakage loss of Kvs value 1 | numeric | % | — |
| EF011080 | Kvs value 2 | numeric | — | — |
| EF011081 | Leakage loss of Kvs value 2 | numeric | % | — |
| EF024116 | Characteristic curve | alphanumeric | — |
|
| EF020451 | Built-in pressure relief valve | logical | — | — |
| EF011082 | Reversing valve | logical | — | — |
| EF001719 | Number of mounting holes | numeric | — | — |
| EF011083 | Dead band (all ports closed) | range | ° | — |
| EF020151 | Length of connection 1 | numeric | mm | — |
| EF020153 | Working length connection 1 | numeric | mm | — |
| EF020152 | Length of connection 2 | numeric | mm | — |
| EF020154 | Working length connection 2 | numeric | mm | — |
| EF020159 | Length of connection 3 | numeric | mm | — |
| EF020160 | Working length connection 3 | numeric | mm | — |
| EF020169 | Length of connection 4 | numeric | mm | — |
| EF020168 | Working length connection 4 | numeric | mm | — |
| EF020203 | Length of connection 5 | numeric | mm | — |
| EF020204 | Working length connection 5 | numeric | mm | — |
| EF020405 | Length of connection 6 | numeric | mm | — |
| EF010185 | Working length connection 6 | numeric | mm | — |
| EF020195 | Axle height | numeric | mm | — |
| EF023970 | Supply voltage | alphanumeric | — |
|
| EF000513 | Control signal | alphanumeric | — |
|
| EF011944 | Supporting protocol for BACnet | logical | — | — |
| EF003057 | Supporting protocol for Modbus | logical | — | — |
| EF013386 | Supporting protocol for MP (multi point) | logical | — | — |
| EF000462 | Type of regulation | alphanumeric | — |
|
| EF003636 | Connection cable length | numeric | m | — |
| EF023956 | Return at zero supply voltage | logical | — | — |
| EF021211 | Deactivated when closed | logical | — | — |
| EF021862 | Position reporting system | alphanumeric | — |
|
| EF024110 | End contacts | alphanumeric | — |
|
| EF002978 | Suitable for manual operation | logical | — | — |
| EF021863 | Operating time | numeric | s | — |
| EF005474 | Degree of protection (IP) | alphanumeric | — |
|
| EF023037 | Max. electric power input | numeric | VA | — |
| EF011084 | With integrated flow measurement | logical | — | — |