etim 7.0 · Class
EC003249Data and communication cable (copper)
Definition not reported by the standard.
Synonyms: Cable, Control cable, Data and communication cable (copper), Data cable, F/FTP, F/UTP, Outdoor cable, Railway signalling cable, S/FTP, SF/UTP, Shipboard communication cable, Signal-/telecommunications cable
- Stable identifier
etim:EC003249- Permalink
- /classifications/etim/7.0/EC003249
- Parent
- EG000001 Cables
- Class revision in the standard
- 1
Properties (44)
| Code | Label (EN) | Type | Unit | Allowed values |
|---|---|---|---|---|
| EF010804 | Conductor surface | alphanumeric | — |
|
| EF001621 | Diameter conductor | numeric | mm | — |
| EF000060 | Nominal cross section conductor | numeric | mm² | — |
| EF001692 | AWG-size | numeric | — | — |
| EF001632 | Conductor category | alphanumeric | — |
|
| EF001792 | Number of cores | numeric | — | — |
| EF001688 | Number of stranding elements | numeric | — | — |
| EF001617 | Stranding element | alphanumeric | — |
|
| EF000061 | Core insulation material | alphanumeric | — |
|
| EF011805 | Specification core insulation | alphanumeric | — |
|
| EF000067 | Core identification | alphanumeric | — |
|
| EF001623 | Screen over stranding element | alphanumeric | — |
|
| EF003802 | Stranding | alphanumeric | — |
|
| EF001624 | Screen over stranding | alphanumeric | — |
|
| EF011011 | Longitudinal water blocking cable | logical | — | — |
| EF011012 | Radial water blocking cable | logical | — | — |
| EF001691 | Protective sheath | alphanumeric | — |
|
| EF001024 | Armouring | logical | — | — |
| EF001625 | Material outer sheath | alphanumeric | — |
|
| EF011806 | Specification material outer sheath | alphanumeric | — |
|
| EF001618 | Colour outer sheath | alphanumeric | — |
|
| EF011577 | Reaction-to-fire class according to EN 13501-6 | alphanumeric | — |
|
| EF011578 | Smoke development class according to EN 13501-6 | alphanumeric | — |
|
| EF011579 | Euro class flaming droplets/particles according to EN 13501-6 | alphanumeric | — |
|
| EF011580 | Euro class acidity according to EN 13501-6 | alphanumeric | — |
|
| EF009769 | Halogen free (acc. EN 60754-1/2) | logical | — | — |
| EF003792 | Halogen free (acc. IEC 60754-2) | logical | — | — |
| EF000471 | Flame retardant | alphanumeric | — |
|
| EF008027 | Low smoke (acc. EN 61034-2) | logical | — | — |
| EF003799 | Low smoke (acc. IEC 61034-2) | logical | — | — |
| EF009770 | Oil resistant (acc. EN 60811-404) | logical | — | — |
| EF009842 | Oil resistant (acc. IEC 60811-404) | logical | — | — |
| EF003794 | Insulation integrity in accordance with IEC 60331 | logical | — | — |
| EF001613 | Circuit integrity | alphanumeric | — |
|
| EF003921 | Outer diameter approx. | numeric | mm | — |
| EF011801 | Min. permitted bending radius, moving application with forced guidance | numeric | mm | — |
| EF011802 | Min. permitted bending radius, moving application/free movement | numeric | mm | — |
| EF011803 | Min. permitted bending radius, stationary application/permanent installation | numeric | mm | — |
| EF001685 | Permitted cable outer temperature during assembling/handling | range | °C | — |
| EF001686 | Permitted cable outer temperature after assembling without vibration | range | °C | — |
| EF001619 | Category | alphanumeric | — |
|
| EF008387 | NVP value | numeric | % | — |
| EF003689 | Underground installation | logical | — | — |
| EF000024 | UV resistant | logical | — | — |
Requirement levels are not part of this standard and are not shown.
Change history
Per-class history is not reported. Compare releases to see what changed between versions.