Skip to content
Sign in

ETIM technical information model, English master (unofficial mirror)

License:ODC-By-1.0Community · the product.cloud project (unofficial mirror)Updated · latest release 10.0
  • Validated
  • Community maintained
About access and trust
Open
Immediately usable under the displayed license. Access is separate from the license.
License
ODC-By-1.0 governs use, including for open repositories.
You
No entitlement needed: the content is open.
Validated
Required rulepack checks passed for the named revision.
Community maintained
Maintained by contributors, not the named product authority.
Release 7.0 — pinned
Follow0 Use repository
Hierarchy

etim 7.0 · Class

EC003106Roof element pitched roof

Definition not reported by the standard.

Synonyms: Roof element pitched roof

Stable identifier
etim:EC003106
Class revision in the standard
1

Properties (21)

Properties of EC003106 in English
CodeLabel (EN)TypeUnitAllowed values
EF000010Modelalphanumeric—
  • EV012641 Double boarding
  • EV012642 Single boarding
  • EV023957 Sandwich
  • EV000154 Other
EF000155Insulationalphanumeric—
  • EV022017 EPS
  • EV004920 Mineral wool
  • EV021692 PIR (polyisocianurate)
  • EV000154 Other
EF010239Suitable for roofingalphanumeric—
  • EV012645 Tiles / slates
  • EV012646 Bituminous waterproofing
  • EV000163 Polyvinyl chloride (PVC)
  • EV012647 Reed tied
  • EV012648 Reed screwed
  • EV012649 Metal ventilated
  • EV012650 Metal non-ventilated
  • EV012651 Asphalt shingles
  • EV012659 Green roof
  • EV000154 Other
EF010240Suitable for substructurealphanumeric—
  • EV012652 Purlins and wall plates
  • EV012653 Loadbearing walls and/or rafters
  • EV012654 Rafters
  • EV012656 Existing roof deck without battens
  • EV012657 Existing roof deck with battens or existing roof elements
  • EV012658 Isolation from the inside between the purlins
  • EV000154 Other
EF001438Lengthnumericmm—
EF000008Widthnumericmm—
EF004810Insulation thicknessnumericmm—
EF025672Overall thicknessnumericmm—
EF010241Gutter overhangnumericmm—
EF010242Spannumericmm—
EF010600Amount of span fieldsalphanumeric—
  • EV013128 1-field
  • EV013129 2-fields
  • EV013130 Multiple fields
EF025368Weight per m²numerickg—
EF010243Max. roofing load per m2numerickg—
EF020004Roof pitchrange°—
EF007828Noise attenuationnumericdB—
EF010245Thermal resistance valuenumeric——
EF010107Edge finishalphanumeric—
  • EV000164 Straight
  • EV012623 Tongue and groove
  • EV012622 Rabbet
  • EV000154 Other
EF010262Material interior finishalphanumeric—
  • EV020960 Chipboard
  • EV020490 Plasterboard
  • EV005650 Gypsum fibre board
  • EV012400 Plywood
  • EV012666 OSB
  • EV023863 Pine
  • EV000154 Other
EF000115Perforatedlogical——
EF010534Suitable for clean brickworklogical——
EF000007Colouralphanumeric—
  • EV000235 Green
  • EV000202 White
  • EV000154 Other

Requirement levels are not part of this standard and are not shown.

Change history

Per-class history is not reported. Compare releases to see what changed between versions.

    Data: ETIM International · ODC-By-1.0