Skip to content
Sign in

ETIM technical information model, English master (unofficial mirror)

License:ODC-By-1.0Community · the product.cloud project (unofficial mirror)Updated · latest release 10.0
  • Validated
  • Community maintained
About access and trust
Open
Immediately usable under the displayed license. Access is separate from the license.
License
ODC-By-1.0 governs use, including for open repositories.
You
No entitlement needed: the content is open.
Validated
Required rulepack checks passed for the named revision.
Community maintained
Maintained by contributors, not the named product authority.
Release 8.0 — pinned
Follow0 Use repository
Hierarchy

etim 8.0 · Class

EC003064Internal wall brick

Definition not reported by the standard.

Synonyms: Inner wall brick, Internal wall brick

Stable identifier
etim:EC003064
Class revision in the standard
3

Properties (23)

Properties of EC003064 in English
CodeLabel (EN)TypeUnitAllowed values
EF002169Materialalphanumeric—
  • EV000079 Concrete
  • EV012516 Aerated concrete
  • EV012517 Plaster
  • EV012518 Lime sand brick
  • EV012519 Ceramic (perforated)
  • EV012520 Ceramic (full)
  • EV000154 Other
EF000443Connectionalphanumeric—
  • EV012486 Tongue and groove
  • EV000880 Flat
  • EV000154 Other
EF020848Length (nominal)numericmm—
EF020849Width (nominal)numericmm—
EF014664Height (nominal)numericmm—
EF020855Length (production size)numericmm—
EF020856Width (production size)numericmm—
EF014665Height (production size)numericmm—
EF000167Weightnumerickg—
EF026343Number per square meternumeric——
EF014654Size tolerance according to EN 772-16alphanumeric—
  • EV017078 T1 (between 0.4 x nominal mm and 3 mm)
  • EV017079 T2 (between 0.25 x nominal mm and 2 mm)
  • EV017076 Tm (statement manufacturer)
EF014655Size spreading according to EN 772-16alphanumeric—
  • EV017087 R1 (0.6 x nominal size mm)
  • EV017086 R2 (0.3 x nominale size mm)
  • EV017077 Rm (statement manufacturer)
EF010248Voluminous massnumerickg/m³—
EF014656Tolerance voluminous mass according to EN 772-13alphanumeric—
  • EV017080 D1 (±10%)
  • EV017081 D2 (±5%)
  • EV017082 Dm (statement manufacturer)
EF026345Average normalized compressive strengthnumericN/mm²—
EF014658Water vapour permeability (µ) according to EN 1745alphanumeric—
  • EV017108 5/10
  • EV000154 Other
EF010126Suitable for visible masonrylogical——
EF014659Thermal conductivity according to EN 1745 (Lambda 10, dry, stone)numericW/(m.K)—
EF010338Thermal conductivity according to EN 1745 (90/90)numericW/(m.K)—
EF014662Content of active soluble salts according to EN 772-5alphanumeric—
  • EV017083 S0 (no requirements)
  • EV017084 S1 (<0.17 % Na+K, <0.08 % Mg)
  • EV017085 S2 (<0.06 % Na+K, <0.03 % Mg)
EF014683Water absorption according to EN 772-21numeric%—
EF010460Initial water suction according to EN 772-11alphanumeric—
  • EV012998 IW1 very little absorption <0.5
  • EV012999 IW2 moderate absorption 0.5 - 1.5
  • EV013000 IW3 regular absorption 1.5 to 4
  • EV013001 IW4 high absorption >4
EF026338Euro fire class according to EN 13501-1alphanumeric—
  • EV010732 A1
  • EV010733 A2
  • EV000074 B
  • EV000084 C
  • EV000413 D
  • EV000647 E
  • EV000334 F
  • EV000154 Other

Requirement levels are not part of this standard and are not shown.

Change history

Per-class history is not reported. Compare releases to see what changed between versions.

    Data: ETIM International · ODC-By-1.0