Skip to content
Sign in

ETIM technical information model, English master (unofficial mirror)

License:ODC-By-1.0Community · the product.cloud project (unofficial mirror)Updated · latest release 10.0
  • Validated
  • Community maintained
About access and trust
Open
Immediately usable under the displayed license. Access is separate from the license.
License
ODC-By-1.0 governs use, including for open repositories.
You
No entitlement needed: the content is open.
Validated
Required rulepack checks passed for the named revision.
Community maintained
Maintained by contributors, not the named product authority.
Latest on main — may changePin this view to commit c61267fcfe43
Follow0 Use repository
Hierarchy

etim 10.0 · Class

EC002911Arc detection and mitigation system

Definition not reported by the standard.

Synonyms: Active arc-fault mitigation system, Arc detection and mitigation system, Arc detection system, Arc fault protection system, Arc flash protection, Arc mitigation system, IACD, Internal arc-fault control device, Optical-based internal arc-detection

Stable identifier
etim:EC002911
Class revision in the standard
4

Properties (29)

Properties of EC002911 in English
CodeLabel (EN)TypeUnitAllowed values
EF000010Modelalphanumeric—
  • EV002153 Compact
  • EV000241 Modular
  • EV000154 Other
EF000119Expandablelogical——
EF017559Switchgear technologyalphanumeric—
  • EV013601 Air insulated
  • EV000154 Other
EF000312Overcurrent protectionlogical——
EF017549Type of arc light sensoralphanumeric—
  • EV019971 Fibre optic loop sensor
  • EV019972 Point/lens-type sensor
  • EV000154 Other
EF017550Max. number of arc sensorsnumeric——
EF017551Number of trip outputsnumeric——
EF017552Operation trip timenumericms—
EF003978Rated control supply voltage AC 50 HzrangeV—
EF003979Rated control supply voltage AC 60 HzrangeV—
EF003980Rated control supply voltage DCrangeV—
EF017554Rated current of phase/neutral current inputsnumericA—
EF008242Voltage type for actuatingalphanumeric—
  • EV000460 AC
  • EV000509 AC/DC
  • EV000461 DC
EF000003Mounting methodalphanumeric—
  • EV000945 Surface mounting
  • EV000242 DIN rail
  • EV000383 Flush-mounted
  • EV008241 Front mounting
  • EV000868 Wall mounting
  • EV000154 Other
EF003961Type of electric connectionalphanumeric—
  • EV005752 Spring clamp connection
  • EV005753 Screw-/spring clamp connection
  • EV000415 Screw connection
  • EV000154 Other
EF000318Number of inputsnumeric——
EF017557Number of binary inputsnumeric——
EF017558Number of binary outputsnumeric——
EF008256Number of contacts as normally open contactnumeric——
EF008255Number of contacts as normally closed contactnumeric——
EF008257Number of contacts as change-over contactnumeric——
EF017553Number of phase/neutral current inputsnumeric——
EF017555Number of fast fibre optic signal inputs/outputsnumeric——
EF016191Circuit-breaker failure protection (ANSI 50BF)logical——
EF003118Degree of protection (IP), front sidealphanumeric—
  • EV006419 IP54
  • EV000154 Other
EF017556Degree of protection (IP), rear sidealphanumeric—
  • EV006405 IP20
  • EV000154 Other
EF000040Heightnumericmm—
EF000008Widthnumericmm—
EF000049Depthnumericmm—

Requirement levels are not part of this standard and are not shown.

Change history

Per-class history is not reported. Compare releases to see what changed between versions.

    Data: ETIM International · ODC-By-1.0