etim 5.0 · Class
EC002549Light curtain
Definition not reported by the standard.
Synonyms: Light curtain
- Stable identifier
etim:EC002549- Permalink
- /classifications/etim/5.0/EC002549
- Class revision in the standard
- 4
Properties (38)
| Code | Label (EN) | Label (DE) | Type | Unit | Allowed values |
|---|---|---|---|---|---|
| EF003945 | Number of semiconductor outputs with signalling function | Number of semiconductor outputs with signalling functionen fallback: no German translation | numeric | — | — |
| EF003946 | Number of contact energized outputs with signalling function | Number of contact energized outputs with signalling functionen fallback: no German translation | numeric | — | — |
| EF003951 | Number of protected semiconductor outputs | Number of protected semiconductor outputsen fallback: no German translation | numeric | — | — |
| EF003952 | Number of protected contact energized outputs | Number of protected contact energized outputsen fallback: no German translation | numeric | — | — |
| EF003955 | Fade-out possible | Fade-out possibleen fallback: no German translation | logical | — | — |
| EF003956 | Type of interface for safety communication | Type of interface for safety communicationen fallback: no German translation | alphanumeric | — |
|
| EF003959 | Type of switching output of the OSSD | Type of switching output of the OSSDen fallback: no German translation | alphanumeric | — |
|
| EF003961 | Type of electric connection | Type of electric connectionen fallback: no German translation | alphanumeric | — |
|
| EF003982 | Operation agent-safety class | Operation agent-safety classen fallback: no German translation | alphanumeric | — |
|
| EF007094 | Width sensor | Width sensoren fallback: no German translation | numeric | mm | — |
| EF007283 | Height of sensor | Height of sensoren fallback: no German translation | numeric | mm | — |
| EF007334 | Length of sensor | Length of sensoren fallback: no German translation | numeric | mm | — |
| EF003991 | Detection power for test bodies | Detection power for test bodiesen fallback: no German translation | numeric | mm | — |
| EF003997 | Explosion safety category for gas | Explosion safety category for gasen fallback: no German translation | alphanumeric | — |
|
| EF003998 | Explosion safety category for dust | Explosion safety category for dusten fallback: no German translation | alphanumeric | — |
|
| EF000507 | Cascadable | Cascadableen fallback: no German translation | logical | — | — |
| EF004032 | Scope of delivery of the one-way system | Scope of delivery of the one-way systemen fallback: no German translation | alphanumeric | — |
|
| EF004035 | Max. output current at protected output | Max. output current at protected outputen fallback: no German translation | numeric | mA | — |
| EF002386 | Ambient temperature | Ambient temperatureen fallback: no German translation | range | °C | — |
| EF004057 | With muting function | With muting functionen fallback: no German translation | logical | — | — |
| EF004061 | Override possible | Override possibleen fallback: no German translation | logical | — | — |
| EF004094 | Time of reaction | Time of reactionen fallback: no German translation | numeric | ms | — |
| EF006784 | Resolution of the light curtain | Resolution of the light curtainen fallback: no German translation | numeric | mm | — |
| EF004095 | Reduced resolution | Reduced resolutionen fallback: no German translation | logical | — | — |
| EF004098 | Transmission range of the safety field | Transmission range of the safety fielden fallback: no German translation | numeric | m | — |
| EF004102 | Switching voltage of OSSD at state "high" | Switching voltage of OSSD at state "high"en fallback: no German translation | numeric | V | — |
| EF004103 | Safety field height | Safety field heighten fallback: no German translation | numeric | mm | — |
| EF004105 | Type of safety acc. IEC 61496-1 | Type of safety acc. IEC 61496-1en fallback: no German translation | alphanumeric | — |
|
| EF003978 | Rated control supply voltage Us at AC 50HZ | Rated control supply voltage Us at AC 50HZen fallback: no German translation | range | V | — |
| EF003979 | Rated control supply voltage Us at AC 60HZ | Rated control supply voltage Us at AC 60HZen fallback: no German translation | range | V | — |
| EF003980 | Rated control supply voltage Us at DC | Rated control supply voltage Us at DCen fallback: no German translation | range | V | — |
| EF000187 | Voltage type | Voltage typeen fallback: no German translation | alphanumeric | — |
|
| EF004114 | With beam coding | With beam codingen fallback: no German translation | logical | — | — |
| EF004119 | Clock control possible | Clock control possibleen fallback: no German translation | logical | — | — |
| EF004052 | With monitoring function downstream switching devices | With monitoring function downstream switching devicesen fallback: no German translation | logical | — | — |
| EF004132 | Wavelength of the sensor | Wavelength of the sensoren fallback: no German translation | numeric | nm | — |
| EF004054 | With restart blockage | With restart blockageen fallback: no German translation | logical | — | — |
| EF001597 | Suited for safety functions | Suited for safety functionsen fallback: no German translation | logical | — | — |
Requirement levels are not part of this standard and are not shown.
Change history
Per-class history is not reported. Compare releases to see what changed between versions.