etim 8.0 · Class

EC000837Power cable >= 1 kV, for moving application

Definition not reported by the standard.

Synonyms: Cable, Energy cable, Energy cable >= 1 kV, for moving application, High voltage power cable, Power cable >= 1 kV, for moving application, Trailing cable

Stable identifier
etim:EC000837
Class revision in the standard
8

Properties (30)

Properties of EC000837 in English
CodeLabel (EN)TypeUnitAllowed values
EF001694Nominal cross section main conductorsnumericmm²—
EF011788AWG size main conductorsalphanumeric—
  • EV023451 0000
  • EV005311 000
  • EV008738 00
  • EV000601 0
  • EV000599 1
  • EV000600 2
  • EV000070 4
  • EV002393 6
  • EV002700 8
  • EV007985 10
  • EV007990 12
  • EV013860 14
  • EV007993 16
  • EV013861 18
  • EV007999 20
  • EV020009 22
  • EV016270 23
  • EV003428 24
  • EV003429 26
  • EV003430 27
  • EV001761 28
  • EV000154 Other
EF011791Nominal cross section main conductors (AWG)numerickcmil—
EF001693Number of main coresnumeric——
EF001697Number of pilot/reduced coresnumeric——
EF000061Material core insulationalphanumeric—
  • EV000169 Rubber
  • EV001108 Polyolefin
  • EV000163 Polyvinyl chloride (PVC)
  • EV000154 Other
EF011805Specification core insulationalphanumeric—
  • EV004191 Rubber - ethylene propylene rubber (EPR)
  • EV006293 Rubber - Hard grade Ethylene Propylene Rubber (HEPR)
  • EV000157 Polyethylene (PE)
  • EV000154 Other
EF001695Identification main coresalphanumeric—
  • EV000494 None
  • EV000207 Colour
  • EV003688 Numbers
  • EV000154 Other
EF001696Nominal cross section pilot/reduced conductorsnumericmm²—
EF011792Nominal cross section pilot/reduced conductors (AWG)numeric——
EF007468With protective conductorlogical——
EF001794Suspension elementalphanumeric—
  • EV000494 None
  • EV004245 Hemp
  • EV004246 Aramid fibre
  • EV000179 Steel
  • EV000154 Other
EF001687Torsion resistantlogical——
EF001625Material outer sheathalphanumeric—
  • EV000494 None
  • EV000169 Rubber
  • EV000157 Polyethylene (PE)
  • EV001108 Polyolefin
  • EV004190 Polyurethane (PUR)
  • EV000163 Polyvinyl chloride (PVC)
  • EV000154 Other
EF011806Specification material outer sheathalphanumeric—
  • EV006292 Rubber - chlorinated/chlorosulfonated polyethylene (CPE/CSP)
  • EV004191 Rubber - ethylene propylene rubber (EPR)
  • EV022529 Rubber - Polychloroprene (PCP)
  • EV000157 Polyethylene (PE)
  • EV000154 Other
EF001618Colour outer sheathalphanumeric—
  • EV000206 Black
  • EV000080 Blue
  • EV000083 Brown
  • EV013082 Colourless
  • EV000235 Green
  • EV000270 Grey
  • EV003822 Multi-coloured
  • EV000236 Orange
  • EV000258 Pink
  • EV003609 Purple
  • EV000233 Red
  • EV001560 Turquoise
  • EV000202 White
  • EV000234 Yellow
  • EV000154 Other
EF000471Flame retardantalphanumeric—
  • EV004175 No
  • EV009948 According to IEC/EN 60332-1-2
  • EV010564 According to IEC/EN 60332-3-24
  • EV006303 According to IEC/EN 60332-3-22
  • EV000154 Other
EF009770Oil resistant (according to EN 60811-404)logical——
EF013532Cable geometryalphanumeric—
  • EV000167 Round
  • EV000880 Flat
  • EV000154 Other
EF003796Cable width approx.numericmm—
EF003797Cable height approx.numericmm—
EF003921Outer diameter approx.numericmm—
EF011801Min. permitted bending radius, moving application with forced guidancenumericmm—
EF011802Min. permitted bending radius, moving application/free movementnumericmm—
EF011803Min. permitted bending radius, stationary application/permanent installationnumericmm—
EF001685Permitted cable outer temperature during assembling/handlingrange°C—
EF001686Permitted cable outer temperature after assembling without vibrationrange°C—
EF001790Nominal voltage U0numerickV—
EF001615Nominal voltage UnumerickV—
EF000167Weightnumerickg/km—