Skip to content
Sign in

ETIM technical information model, English master (unofficial mirror)

License:ODC-By-1.0Community · the product.cloud project (unofficial mirror)Updated · latest release 10.0
  • Validated
  • Community maintained
About access and trust
Open
Immediately usable under the displayed license. Access is separate from the license.
License
ODC-By-1.0 governs use, including for open repositories.
You
No entitlement needed: the content is open.
Validated
Required rulepack checks passed for the named revision.
Community maintained
Maintained by contributors, not the named product authority.
Release 10.0 — pinned
Follow0 Use repository
Hierarchy

etim 10.0 · Class

EC000617Trip block for power circuit-breaker

Definition not reported by the standard.

Synonyms: Monitoring unit, Over current protection, Overcurrent protection, Shunt release (for power circuit breaker), Thermal protection, Thermal release, Trip block for power circuit-breaker, Tripping bloc for power circuit-breaker

Stable identifier
etim:EC000617
Class revision in the standard
7

Properties (24)

Properties of EC000617 in English
CodeLabel (EN)TypeUnitAllowed values
EF008234Type of motor protectionalphanumeric—
  • EV014005 Electronic release
  • EV001280 Thermal release
  • EV001281 Thermal/magnetic release
  • EV000154 Other
EF001391Number of polesnumeric——
EF001389Rated permanent current IunumericA—
EF006706Rated switch currentnumericA—
EF002336Overload release current settingrangeA—
EF001413Short-circuit release functionalphanumeric—
  • EV003977 Delayed
  • EV003978 Undelayed
  • EV000494 None
EF018171Current setting delayed short-circuit releaserangeA—
EF018170Current setting undelayed short-circuit releaserangeA—
EF005601With ground fault protection functionlogical——
EF003292External power supply requiredlogical——
EF002991Voltage type (supply voltage)alphanumeric—
  • EV000460 AC
  • EV000461 DC
  • EV000509 AC/DC
EF007532Supply voltage AC 50 HzrangeV—
EF007533Supply voltage AC 60 HzrangeV—
EF007534Supply voltage DCrangeV—
EF001377Number of auxiliary contacts as normally closed contactnumeric——
EF001376Number of auxiliary contacts as normally open contactnumeric——
EF003531Number of auxiliary contacts as change-over contactnumeric——
EF005294Voltage type (operating voltage)alphanumeric—
  • EV000460 AC
  • EV000461 DC
  • EV000509 AC/DC
EF008206Operating voltage AC 50 HzrangeV—
EF008207Operating voltage AC 60 HzrangeV—
EF008208Operating voltage DCrangeV—
EF000008Widthnumericmm—
EF000040Heightnumericmm—
EF000049Depthnumericmm—

Requirement levels are not part of this standard and are not shown.