etim 7.0 · Class
EC000484Energy distributor for construction site
Definition not reported by the standard.
Synonyms: Cable entry cabinet, Cable entry distribution cabinet, Distributor, Distributor case, End distribution enclosure, Energy distributor for construction site, Entry/end distributor enclosure, Mobile end-distributor
- Stable identifier
etim:EC000484- Permalink
- /classifications/etim/7.0/EC000484
- Class revision in the standard
- 6
Properties (30)
| Code | Label (EN) | Type | Unit | Allowed values |
|---|---|---|---|---|
| EF000010 | Model | alphanumeric | — |
|
| EF000227 | Rated current | numeric | A | — |
| EF000446 | Connected load | numeric | kVA | — |
| EF009490 | Number of CEE socket outlets 16 A / 24 V / 2P | numeric | — | — |
| EF009491 | Number of CEE socket outlets 16 A / 230 V / 2P + Earth | numeric | — | — |
| EF009492 | Number of CEE socket outlets 16 A / 400 V / 3P + Earth | numeric | — | — |
| EF000408 | Number of CEE socket outlets 16 A / 400 V / 5P | numeric | — | — |
| EF009157 | Number of CEE socket outlets 32 A / 400 V / 4P | numeric | — | — |
| EF000409 | Number of CEE socket outlets 32 A / 400 V / 5P | numeric | — | — |
| EF000410 | Number of CEE socket outlets 63 A / 400 V / 5P | numeric | — | — |
| EF011974 | Number of CEE socket outlets 125A / 400 V / 5P | numeric | — | — |
| EF000411 | Number of socket outlets with protective contact | numeric | — | — |
| EF011975 | number of socket outlets swiss standard type 13 | numeric | — | — |
| EF011977 | number of socket outlets swiss standard type 15 | numeric | — | — |
| EF011978 | number of socket outlets swiss standard type 23 | numeric | — | — |
| EF011979 | number of socket outlets swiss standard type 25 | numeric | — | — |
| EF000580 | Number of meter panels | numeric | — | — |
| EF005564 | Number of miniature circuit breakers | numeric | — | — |
| EF000057 | Main switch | alphanumeric | — |
|
| EF005581 | Number of poles main switch | numeric | — | — |
| EF007848 | Main switch rated current | numeric | A | — |
| EF009158 | Number of earth leakage switches 10 mA | numeric | — | — |
| EF005542 | Number of earth leakage switches 30 mA | numeric | — | — |
| EF005541 | Number of earth leakage switches 300 mA | numeric | — | — |
| EF005474 | Degree of protection (IP) | alphanumeric | — |
|
| EF007681 | Rated voltage | alphanumeric | — |
|
| EF000008 | Width | numeric | mm | — |
| EF000040 | Height | numeric | mm | — |
| EF000049 | Depth | numeric | mm | — |
| EF001596 | Material housing | alphanumeric | — |
|
Requirement levels are not part of this standard and are not shown.
Change history