etim 5.0 · Class
EC000297Staircase lighting timer
Definition not reported by the standard.
Synonyms: Built-in device, Mini circuit breaker, Relay, Staircase lighting timer, Time switch, Timer clock, Timer relay
- Stable identifier
etim:EC000297- Permalink
- /classifications/etim/5.0/EC000297
- Class revision in the standard
- 5
Properties (27)
| Code | Label (EN) | Label (DE) | Type | Unit | Allowed values |
|---|---|---|---|---|---|
| EF000030 | Function | Functionen fallback: no German translation | alphanumeric | — |
|
| EF000003 | Mounting method | Mounting methoden fallback: no German translation | alphanumeric | — |
|
| EF002950 | Width in number of modular spacings | Width in number of modular spacingsen fallback: no German translation | numeric | — | — |
| EF000218 | Built-in depth | Built-in depthen fallback: no German translation | numeric | mm | — |
| EF001105 | Number of normally open contacts | Number of normally open contactsen fallback: no German translation | numeric | — | — |
| EF001106 | Number of normally closed contacts | Number of normally closed contactsen fallback: no German translation | numeric | — | — |
| EF001107 | Number of change-over contacts | Number of change-over contactsen fallback: no German translation | numeric | — | — |
| EF002952 | Control voltage 1 | Control voltage 1en fallback: no German translation | range | V | — |
| EF002954 | Type of control voltage 1 | Type of control voltage 1en fallback: no German translation | alphanumeric | — |
|
| EF002956 | Frequency control voltage 1 | Frequency control voltage 1en fallback: no German translation | range | Hz | — |
| EF002953 | Control voltage 2 | Control voltage 2en fallback: no German translation | range | V | — |
| EF002955 | Type of control voltage 2 | Type of control voltage 2en fallback: no German translation | alphanumeric | — |
|
| EF002957 | Frequency control voltage 2 | Frequency control voltage 2en fallback: no German translation | range | Hz | — |
| EF006706 | Rated switch current | Rated switch currenten fallback: no German translation | numeric | A | — |
| EF004920 | Max. switching current (cos phi = 0.6) | Max. switching current (cos phi = 0.6)en fallback: no German translation | numeric | A | — |
| EF001129 | Release-delay | Release-delayen fallback: no German translation | range | min | — |
| EF006707 | Push button glow-lamp current | Push button glow-lamp currenten fallback: no German translation | numeric | mA | — |
| EF002960 | Wiring system | Wiring systemen fallback: no German translation | alphanumeric | — |
|
| EF002961 | Pre-warning of switching-off | Pre-warning of switching-offen fallback: no German translation | alphanumeric | — |
|
| EF008074 | Current surge function selectable | Current surge function selectableen fallback: no German translation | logical | — | — |
| EF002962 | Repetitive | Repetitiveen fallback: no German translation | alphanumeric | — |
|
| EF004127 | Supply voltage | Supply voltageen fallback: no German translation | range | V | — |
| EF002991 | Voltage type of supply voltage | Voltage type of supply voltageen fallback: no German translation | alphanumeric | — |
|
| EF004952 | Max. incandescent lamp load | Max. incandescent lamp loaden fallback: no German translation | numeric | W | — |
| EF004971 | Max. load fluorescent lamp | Max. load fluorescent lampen fallback: no German translation | numeric | VA | — |
| EF004972 | Max. load fluorescent lamp (Duo circuit) | Max. load fluorescent lamp (Duo circuit)en fallback: no German translation | numeric | VA | — |
| EF004973 | Max. load fluorescent lamp (parallel compensated) | Max. load fluorescent lamp (parallel compensated)en fallback: no German translation | numeric | VA | — |
Requirement levels are not part of this standard and are not shown.