Skip to content
Sign in

ETIM technical information model, English master (unofficial mirror)

License:ODC-By-1.0Community · the product.cloud project (unofficial mirror)Updated · latest release 10.0
  • Validated
  • Community maintained
About access and trust
Open
Immediately usable under the displayed license. Access is separate from the license.
License
ODC-By-1.0 governs use, including for open repositories.
You
No entitlement needed: the content is open.
Validated
Required rulepack checks passed for the named revision.
Community maintained
Maintained by contributors, not the named product authority.
Release 9.0 — pinned
Follow0 Use repository
Hierarchy

etim 9.0 · Class

EC000210Fire partitioning

Definition not reported by the standard.

Synonyms: Block, Cable box, Duct fire partitioning, End plate, Feed-through block, Fibre silicate plate, Finished fire partition, Fire partitioning, Fire protection correction element, Fire protection pad, Fire protection plate, Fireproof mortar partition, Fireproof partition (soft), Fireproof partition box, Fireproof plate partition, Foam blocks, Foam stopper, Mixing tube, Modular fire partition, Sealing plate, Steel wire grid, Support bracket, Tube of silicon paste, Wall lead-through, Wall text plate

Stable identifier
etim:EC000210
Class revision in the standard
8

Properties (29)

Properties of EC000210 in English
CodeLabel (EN)TypeUnitAllowed values
EF000010Modelalphanumeric—
  • EV007291 Finished fire partition
  • EV018147 Cable box
  • EV003186 Duct fire partitioning
  • EV007452 Fire protection pad
  • EV007562 Modular fire partition
  • EV007565 Fireproof mortar partition
  • EV007619 Fireproof plate partition
  • EV007708 Foam blocks
  • EV007709 Foam stopper
  • EV001598 Fireproof partition box
  • EV007938 Fireproof partition (soft)
  • EV000154 Other
EF000051Shapealphanumeric—
  • EV000195 Quadrangular
  • EV000167 Round
  • EV009709 Three-sided
  • EV000154 Other
EF008489Outer heightnumericmm—
EF008488Outer widthnumericmm—
EF000015Outer diameternumericmm—
EF006588Inner heightnumericmm—
EF006466Inner widthnumericmm—
EF000065Inner diameternumericmm—
EF005457Depthrangemm—
EF008015Plate thickness/product lengthnumericmm—
EF013753Min. wall thicknessnumericmm—
EF006435Min. ceiling thicknessnumericmm—
EF000016Suitable for max. cable diameternumericmm—
EF008141Accessories requiredlogical——
EF015314Suitable for drywalllogical——
EF015315Suitable for solid walllogical——
EF017296Suitable for solid ceilinglogical——
EF017300Suitable for flush floor installationlogical——
EF017301Suitable for flush ceiling installationlogical——
EF017298Suitable for empty plastic pipeslogical——
EF017297Min. clearances required within the fire partitioninglogical——
EF017299Fire partitioning assignable to 100 %logical——
EF000634Max. pressurenumericmbar—
EF005436Weatherprooflogical——
EF007872Volume bin/bagnumerickg—
EF007871Volume can/cartouchenumericml—
EFDE0060Fire resistance class according to DIN 4102-9alphanumeric—
  • EV019754 S30
  • EV019755 S60
  • EV019756 S90
  • EV019757 S120
  • EV019758 S180
EFDE0072Min. fire resistance class according to DIN EN 13502-2alphanumeric—
  • EV023540 EI30
  • EV023541 EI60
  • EV023542 EI90
  • EV023543 EI120
  • EV024057 EI180
EFDE0073Max. fire resistance class according to DIN EN 13502-2alphanumeric—
  • EV023540 EI30
  • EV023541 EI60
  • EV023542 EI90
  • EV023543 EI120
  • EV024057 EI180

Requirement levels are not part of this standard and are not shown.

Change history

Per-class history is not reported. Compare releases to see what changed between versions.

    Data: ETIM International · ODC-By-1.0