etim 9.0 · Class
EC003778Air cooler (refrigeration technology)
Definition not reported by the standard.
Synonyms: Air Cooler, Air cooler (Refrigeration technique), Air cooler (refrigeration technology), Dual discharge blow through device, Evaporator, Industrial air cooled evaporator, Single discharge blow through device, Single discharge draw through
- Stable identifier
etim:EC003778- Permalink
- /classifications/etim/9.0/EC003778
- Parent
- EG015230 Cooling systems
- Class revision in the standard
- 1
Properties (44)
| Code | Label (EN) | Type | Unit | Allowed values |
|---|---|---|---|---|
| EF000010 | Model | alphanumeric | — |
|
| EF000041 | Application | alphanumeric | — |
|
| EF013579 | Suitable for type of refrigerant R22 | logical | — | — |
| EF013567 | Suitable for type of refrigerant R32 | logical | — | — |
| EF013580 | Suitable for type of refrigerant R290 | logical | — | — |
| EF013569 | Suitable for type of refrigerant R134a | logical | — | — |
| EF013581 | Suitable for type of refrigerant R401a | logical | — | — |
| EF013582 | Suitable for type of refrigerant R402a | logical | — | — |
| EF013568 | Suitable for type of refrigerant R404a | logical | — | — |
| EF013583 | Suitable for type of refrigerant R407c | logical | — | — |
| EF013584 | Suitable for type of refrigerant R413a | logical | — | — |
| EF013585 | Suitable for type of refrigerant R417a | logical | — | — |
| EF013570 | Suitable for type of refrigerant R507 | logical | — | — |
| EF013571 | Suitable for type of refrigerant R717 | logical | — | — |
| EF013572 | Suitable for type of refrigerant R744 (CO2) | logical | — | — |
| EF002310 | Suitable for glycol | logical | — | — |
| EF013573 | Total cooling capacity at 0/-8 °C, R404a | numeric | kW | — |
| EF013586 | Total cooling capacity at 10/0 °C, R404a | numeric | kW | — |
| EF013588 | Total cooling capacity at -18/-25 °C, R404a | numeric | kW | — |
| EF010846 | Lamella distance | numeric | mm | — |
| EF022301 | Throw | range | m | — |
| EF006340 | Air volume | range | m³/h | — |
| EF000040 | Height | numeric | mm | — |
| EF000008 | Width | numeric | mm | — |
| EF000049 | Depth | numeric | mm | — |
| EF000167 | Weight | numeric | kg | — |
| EF000928 | Number of fans | numeric | — | — |
| EF013246 | Fan diameter | numeric | mm | — |
| EF021724 | Fan control system | alphanumeric | — |
|
| EF003625 | Connection voltage | numeric | V | — |
| EF000351 | Number of phases | numeric | — | — |
| EF000034 | Frequency | numeric | Hz | — |
| EF020449 | Max. operating pressure | numeric | bar | — |
| EF013262 | Max. sound level (at a distance of 10 metres) | numeric | dB(A) | — |
| EF013263 | Connection of fluid pipe | alphanumeric | — |
|
| EF024968 | Outer pipe diameter of fluid pipe | numeric | mm | — |
| EF013264 | Connection suction pipe | alphanumeric | — |
|
| EF020139 | Outer pipe diameter suction pipe | numeric | mm | — |
| EF020003 | Material heat exchanger | alphanumeric | — |
|
| EF000524 | Heat exchanger surface | numeric | m² | — |
| EF020510 | Condensate connection | alphanumeric | — |
|
| EF002274 | Type of defrost | alphanumeric | — |
|
| EF001596 | Housing material | alphanumeric | — |
|
| EF000136 | Housing colour | alphanumeric | — |
|
Requirement levels are not part of this standard and are not shown.
Change history
Per-class history is not reported. Compare releases to see what changed between versions.