etim 9.0 · Class
EC003251Power cable >= 1 kV, for permanent installation
Definition not reported by the standard.
Synonyms: Airport lighting cable, Cable, Connection cable, Energy cable, Energy cable >= 1 kV, for permanent installation, Extra high voltage power cable, High voltage power cable, Ignition cable, Low voltage power cable, Marine cable, Medium voltage power cable, Offshore cable, Power cable >= 1 kV, for permanent installation, Ship power cable, Shipboard cable, Shipboard low voltage cable
- Stable identifier
etim:EC003251- Permalink
- /classifications/etim/9.0/EC003251
- Parent
- EG000001 Cables
- Class revision in the standard
- 3
Properties (85)
| Code | Label (EN) | Type | Unit | Allowed values |
|---|---|---|---|---|
| EF001622 | Conductor material | alphanumeric | — |
|
| EF010804 | Conductor surface | alphanumeric | — |
|
| EF000060 | Nominal cross section conductor | numeric | mm² | — |
| EF011789 | AWG size | alphanumeric | — |
|
| EF011790 | Nominal cross section conductor (AWG) | numeric | kcmil | — |
| EF001621 | Diameter conductor | numeric | mm | — |
| EF001632 | Conductor category | alphanumeric | — |
|
| EF017357 | Number of strands per conductor | numeric | — | — |
| EF017358 | Strand diameter | numeric | mm | — |
| EF013551 | Conductor resistance at 20 °C | numeric | Ohm/km | — |
| EF001620 | Shape of conductor | alphanumeric | — |
|
| EF001792 | Number of cores | numeric | — | — |
| EF000061 | Material core insulation | alphanumeric | — |
|
| EF011805 | Specification core insulation | alphanumeric | — |
|
| EF013766 | Core identification according to HD 308 S2 | logical | — | — |
| EF000067 | Core identification | alphanumeric | — |
|
| EF001637 | Laminated sheath | logical | — | — |
| EF001638 | Fibre optic elements | logical | — | — |
| EF007468 | With protective conductor | logical | — | — |
| EF001700 | Inner semi-conducting layer | logical | — | — |
| EF001701 | Outer semi-conducting layer | logical | — | — |
| EF001791 | Screen | logical | — | — |
| EF001029 | Drain wire | logical | — | — |
| EF001027 | Lead sheath | logical | — | — |
| EF003804 | Protective barrier | alphanumeric | — |
|
| EF001683 | Armouring/reinforcement | alphanumeric | — |
|
| EF013440 | Material armouring | alphanumeric | — |
|
| EF011012 | Radial water blocking cable | logical | — | — |
| EF001697 | Number of pilot/reduced conductors | numeric | — | — |
| EF001696 | Nominal cross section pilot/reduced conductors | numeric | mm² | — |
| EF011792 | Nominal cross section pilot/reduced conductors (AWG) | numeric | — | — |
| EF003795 | Concentric conductor | alphanumeric | — |
|
| EF001800 | Nominal cross section concentric conductor | numeric | mm² | — |
| EF001625 | Material outer sheath | alphanumeric | — |
|
| EF011806 | Specification material outer sheath | alphanumeric | — |
|
| EF001618 | Colour outer sheath | alphanumeric | — |
|
| EF013532 | Cable geometry | alphanumeric | — |
|
| EF008389 | Conductive coating | logical | — | — |
| EF001795 | Longitudinal water blocking conductors | logical | — | — |
| EF001704 | Longitudinal water blocking screen | logical | — | — |
| EF016492 | Flame retardant according to IEC 60332-1-2 | logical | — | — |
| EF016493 | Flame retardant according to IEC 60332-3-21 (Cat A F/R) | logical | — | — |
| EF016494 | Flame retardant according to IEC 60332-3-22 (Cat A) | logical | — | — |
| EF016495 | Flame retardant according to IEC 60332-3-23 (Cat B) | logical | — | — |
| EF016496 | Flame retardant according to IEC 60332-3-24 (Cat C) | logical | — | — |
| EF016497 | Flame retardant according to IEC 60332-3-25 (Cat D) | logical | — | — |
| EF003799 | Low smoke according to EN IEC 61034-2 | logical | — | — |
| EF016498 | Halogen free according to EN IEC 60754-1 | logical | — | — |
| EF003792 | Halogen free according to EN IEC 60754-2 | logical | — | — |
| EF016500 | Halogen free according to EN IEC 60754-3 | logical | — | — |
| EF011577 | Reaction-to-fire according to EN 13501-6: Class | alphanumeric | — |
|
| EF011578 | Reaction-to-fire according to EN 13501-6: Smoke production | alphanumeric | — |
|
| EF011579 | Reaction-to-fire according to EN 13501-6: Flaming droplets/particles | alphanumeric | — |
|
| EF011580 | Reaction-to-fire according to EN 13501-6: Acidity | alphanumeric | — |
|
| EF016616 | Circuit integrity according to IEC 60331-1 | alphanumeric | — |
|
| EF016617 | Circuit integrity according to IEC 60331-2 | alphanumeric | — |
|
| EF016618 | Circuit integrity according to IEC 60331-3 | alphanumeric | — |
|
| EF016621 | Circuit integrity according to EN 50200 | alphanumeric | — |
|
| EF016490 | Circuit integrity according to EN 50200 annex E | logical | — | — |
| EF009770 | Oil resistant according to EN IEC 60811-404 | logical | — | — |
| EF003796 | Cable width approx. | numeric | mm | — |
| EF003797 | Cable height approx. | numeric | mm | — |
| EF003921 | Outer diameter approx. | numeric | mm | — |
| EF011803 | Min. permitted bending radius, stationary application/permanent installation | numeric | mm | — |
| EF013801 | Max. tensile strength during installation | numeric | kN | — |
| EF000167 | Weight | numeric | kg/km | — |
| EF003803 | Max. conductor temperature | numeric | °C | — |
| EF001685 | Permitted cable outer temperature during assembling/handling | range | °C | — |
| EF001686 | Permitted cable outer temperature after assembling without vibration | range | °C | — |
| EF001790 | Nominal voltage U0 | numeric | kV | — |
| EF001615 | Nominal voltage U | numeric | kV | — |
| EF013442 | Nominal equivalent cross section of reinforcement | numeric | mm² | — |
| EF000024 | UV resistant | logical | — | — |
| EF003689 | Suitable for underground installation | logical | — | — |
| EF013771 | Suitable as installation cable | logical | — | — |
| EF013772 | Certified for shipboard application | logical | — | — |
| EF013773 | Suitable as medium-voltage cable | logical | — | — |
| EF013774 | Suitable as high-voltage cable | logical | — | — |
| EF013775 | Certified as airport lighting cable | logical | — | — |
| EF007960 | With rodent protection | logical | — | — |
| EFDE0050 | Insulation integrity according to DIN VDE 0472-814 | alphanumeric | — |
|
| EFDE0051 | Circuit integrity according to DIN 4102-12 | alphanumeric | — |
|
| EFUK0001 | Circuit integrity according to BS 6387 CWZ | logical | — | — |
| EFUK0004 | Circuit integrity according to BS 8434-2 | logical | — | — |
| EFUK0005 | Circuit integrity according to BS 8491 | alphanumeric | — |
|
Requirement levels are not part of this standard and are not shown.
Change history
Per-class history is not reported. Compare releases to see what changed between versions.