Hierarchy

etim 9.0 · Class

EC001037Motor starter/motor starter combination

Definition not reported by the standard.

Synonyms: Contactor automatic, Direct starter, Motor protection switch, Motor protective circuit-breaker, Motor starter, Motor starter combination, Motor starter/motor starter combination, Reversing starter, Star-delta starter, Starter

Stable identifier
etim:EC001037
Class revision in the standard
9

Properties (59)

Properties of EC001037 in English
CodeLabel (EN)TypeUnitAllowed values
EF009598Type of motor starteralphanumeric—
  • EV004003 Direct online starter (DOL)
  • EV010690 Repair switch
  • EV004004 Star-delta starter
  • EV004002 Reversing starter
  • EV000154 Other
EF006691With short-circuit releaselogical——
EF003978Rated control supply voltage AC 50 HzrangeV—
EF003979Rated control supply voltage AC 60 HzrangeV—
EF003980Rated control supply voltage DCrangeV—
EF008242Voltage type for actuatingalphanumeric—
  • EV000460 AC
  • EV000461 DC
  • EV000509 AC/DC
EF009599Rated operation power at AC-3, 230 V, 3-phasenumerickW—
EF001364Rated operation power at AC-3, 400 VnumerickW—
EF009600Rated power, 460 V, 60 Hz, 3-phasenumerickW—
EF009601Rated power, 575 V, 60 Hz, 3-phasenumerickW—
EF001443Rated operation current IenumericA—
EF009602Rated operation current at AC-3, 400 VnumericA—
EF002336Overload release current settingrangeA—
EF009607Rated conditional short-circuit current, type 1, 480 Y/277 VnumericA—
EF009608Rated conditional short-circuit current, type 1, 600 Y/347 VnumericA—
EF009606Rated conditional short-circuit current, type 2, 230 VnumericA—
EF009605Rated conditional short-circuit current, type 2, 400 VnumericA—
EF000346Power consumptionnumericW—
EF001376Number of auxiliary contacts as normally open contactnumeric——
EF001377Number of auxiliary contacts as normally closed contactnumeric——
EF009603Ambient temperature, upper operating limitnumeric°C—
EF009604Temperature compensated overload protectionlogical——
EF006668Release classalphanumeric—
  • EV011240 CLASS 10 A
  • EV008931 CLASS 10
  • EV008932 CLASS 20
  • EV013964 CLASS 30
  • EV009222 Adjustable
  • EV000154 Other
EF006819Type of electrical connection of main circuitalphanumeric—
  • EV005752 Spring clamp connection
  • EV003968 Flat plug-in connection
  • EV003963 PCB connection
  • EV000415 Screw connection
  • EV000414 Plug-in connection
  • EV000154 Other
EF006979Type of electrical connection for auxiliary- and control current circuitalphanumeric—
  • EV000415 Screw connection
  • EV005752 Spring clamp connection
  • EV000414 Plug-in connection
  • EV000154 Other
EF003972Rail mounting possiblelogical——
EF000278With transformerlogical——
EF001372Number of command positionsnumeric——
EF001433Suitable for emergency stoplogical——
EF012390Coordination class according to IEC 60947-4-3alphanumeric—
  • EV006626 Class 1
  • EV006627 Class 2
EF001965Number of indicator lightsnumeric——
EF003426External reset possiblelogical——
EF006693With fuselogical——
EF005474Degree of protection (IP)alphanumeric—
  • EV006404 IP00
  • EV006606 IP10
  • EV006607 IP12
  • EV006405 IP20
  • EV006406 IP21
  • EV006608 IP22
  • EV006407 IP23
  • EV006408 IP24
  • EV006409 IP2X
  • EV006410 IP30
  • EV006411 IP31
  • EV006412 IP32
  • EV006609 IP33
  • EV006413 IP34
  • EV006414 IP3X
  • EV006415 IP40
  • EV006416 IP41
  • EV006417 IP42
  • EV006610 IP43
  • EV006418 IP44
  • EV006611 IP45
  • EV006612 IP50
  • EV006613 IP52
  • EV006614 IP53
  • EV006419 IP54
  • EV006420 IP55
  • EV006615 IP56
  • EV006616 IP57
  • EV006617 IP58
  • EV006618 IP64
  • EV006421 IP65
  • EV008925 IP65/IP67
  • EV006422 IP66
  • EV006423 IP67
  • EV013221 IP67/IP69K
  • EV009289 IP67K
  • EV006619 IP68
  • EV006620 IPX0
  • EV006621 IPX4
  • EV006622 IPX7
  • EV000154 Other
EF011959Degree of protection (NEMA)alphanumeric—
  • EV000599 1
  • EV014035 3R
  • EV000070 4
  • EV014040 4X
  • EV007990 12
  • EV000154 Other
EF003050Supporting protocol for TCP/IPlogical——
EF003052Supporting protocol for PROFIBUSlogical——
EF003053Supporting protocol for CANlogical——
EF003054Supporting protocol for INTERBUSlogical——
EF003051Supporting protocol for ASIlogical——
EF003057Supporting protocol for Modbuslogical——
EF003058Supporting protocol for Data-Highwaylogical——
EF003059Supporting protocol for DeviceNetlogical——
EF003060Supporting protocol for SUCONETlogical——
EF003017Supporting protocol for LONlogical——
EF007525Supporting protocol for PROFINET IOlogical——
EF007524Supporting protocol for PROFINET CBAlogical——
EF006657Supporting protocol for SERCOSlogical——
EF007522Supporting protocol for Foundation Fieldbuslogical——
EF007521Supporting protocol for EtherNet/IPlogical——
EF007519Supporting protocol for AS-Interface Safety at Worklogical——
EF007520Supporting protocol for DeviceNet Safetylogical——
EF006662Supporting protocol for INTERBUS-Safetylogical——
EF007526Supporting protocol for PROFIsafelogical——
EF007527Supporting protocol for SafetyBUS plogical——
EF003062Supporting protocol for other bus systemslogical——
EF000008Widthnumericmm—
EF000040Heightnumericmm—
EF000049Depthnumericmm—

Requirement levels are not part of this standard and are not shown.