Skip to content
Sign in

ETIM technical information model, English master (unofficial mirror)

License:ODC-By-1.0Community · the product.cloud project (unofficial mirror)Updated · latest release 10.0
  • Validated
  • Community maintained
About access and trust
Open
Immediately usable under the displayed license. Access is separate from the license.
License
ODC-By-1.0 governs use, including for open repositories.
You
No entitlement needed: the content is open.
Validated
Required rulepack checks passed for the named revision.
Community maintained
Maintained by contributors, not the named product authority.
Release 8.0 — pinned
Follow0 Use repository
Hierarchy

etim 8.0 · Class

EC001286Auxiliary device for distribution board devices

Definition not reported by the standard.

Synonyms: Arc-fault detection Unit (AFD), Auxiliary contact unit for distribution board, Auxiliary device for distribution board devices, Auxiliary switch, Fault-signal switch, Fire protection switch, Monitoring unit, Monitoring unit with automatic reclosing, Remote drive, Remote release, Remote turn-on switch, Shunt release (for power circuit breaker), Signalling switch, Under voltage coil

Stable identifier
etim:EC001286
Class revision in the standard
8

Properties (14)

Properties of EC001286 in English
CodeLabel (EN)TypeUnitAllowed values
EF007826Device fittingalphanumeric—
  • EV000416 Earth leakage switch
  • EV009774 Earth leakage circuit breaker
  • EV000646 Miniature circuit breaker (MCB)
  • EV009775 Earth leakage circuit breaker and miniature circuit breaker (MCB)
  • EV010066 Auxiliary switch / relay
  • EV000154 Other
  • EV000028 Universal
EF008146Additional equipmentalphanumeric—
  • EV009614 Shunt release (for power circuit breaker)
  • EV012272 Fire protection switch
  • EV009771 Remote drive
  • EV009772 Remote release
  • EV009773 Remote turn-on switch
  • EV009832 Auxiliary switch
  • EV009833 Auxiliary switch / fault-signal switch
  • EV010082 Signalling switch
  • EV010155 Under voltage coil
  • EV010146 Monitoring unit with automatic reclosing
  • EV010145 Monitoring unit
  • EV000154 Other
EF002581Installed at the factorylogical——
EF002950Width in number of modular spacingsnumeric——
EF008256Number of contacts as normally open contactnumeric——
EF008255Number of contacts as normally closed contactnumeric——
EF008257Number of contacts as change-over contactnumeric——
EF007613Number of fault-signal switchesnumeric——
EF006706Rated switch currentnumericA—
EF000228Rated voltagenumericV—
EF008242Voltage type for actuatingalphanumeric—
  • EV000460 AC
  • EV000461 DC
  • EV000509 AC/DC
EF008727With auto test for earth leakage functionlogical——
EF008729Suitable for max. number of poles main contact unit (total)numeric——
EF008730Suitable for max. current main contact unitnumericA—

Requirement levels are not part of this standard and are not shown.