etim 10.0 · Class
EC012346Delivery station collective heating
Definition not reported by the standard.
Synonyms: Block heating station, Block heating unit, Delivery station collective heating, Delivery station for hydronic heating circuits, District heat transfer station, District heating substation, District heating unit, Dwelling station, Heat interface unit, Home heating station, Tap water heater
- Stable identifier
etim:EC012346- Permalink
- /classifications/etim/10.0/EC012346
- Class revision in the standard
- 5
Properties (81)
| Code | Label (EN) | Type | Unit | Allowed values |
|---|---|---|---|---|
| EF016346 | Suitable for district heating | logical | — | — |
| EF016348 | Suitable for block heating | logical | — | — |
| EF011111 | Suitable for heat pump | logical | — | — |
| EF016117 | Suitable for solar heating | logical | — | — |
| EF024797 | Suitable for heating | logical | — | — |
| EF024798 | Suitable for cooling | logical | — | — |
| EF021195 | Suitable for hot tap water | logical | — | — |
| EF002221 | With circulation pump | logical | — | — |
| EF015444 | Pump control signal | alphanumeric | — |
|
| EF015496 | High efficiency pump (compliant with EC 547/2012 and EC 641/2009) | logical | — | — |
| EF000456 | With heat exchanger | logical | — | — |
| EF020003 | Material heat exchanger | alphanumeric | — |
|
| EF015504 | Soldering material heat exchanger | alphanumeric | — |
|
| EF021076 | Exchanger with dual separation | logical | — | — |
| EF015505 | Heat exchanger fully sealed | logical | — | — |
| EF009377 | With fitting piece for heat meter | logical | — | — |
| EF018850 | Length fitting piece for heat meter | range | mm | — |
| EF024028 | With immersion tube | logical | — | — |
| EF009378 | With heat meter | logical | — | — |
| EF015468 | With fitting piece for cold water meter | logical | — | — |
| EF018851 | Length fitting piece for cold water meter | range | mm | — |
| EF018853 | With fitting piece for hot water meter | logical | — | — |
| EF018854 | Length fitting piece for hot water meter | range | mm | — |
| EF009379 | Primary supply temperature | range | °C | — |
| EF018852 | Secondary supply temperature | range | °C | — |
| EF022016 | Max. primary operating pressure | numeric | kPa | — |
| EF022017 | Max. secondary operating pressure | numeric | kPa | — |
| EF018855 | Max. operating pressure tap water | numeric | kPa | — |
| EF009380 | Primary pressure difference | range | kPa | — |
| EF020351 | Tap capacity at 60 °C, continuous | numeric | l/min | — |
| EF018856 | Max. warm water at 10 °C cold water, 45 °C warm water and 50 °C primary flow | numeric | l/min | — |
| EF018857 | Max. warm water at 10 °C cold water, 45 °C warm water and 55 °C primary flow | numeric | l/min | — |
| EF018858 | Max. warm water at 10 °C cold water, 45 °C warm water and 60 °C primary flow | numeric | l/min | — |
| EF018859 | Max. warm water at 10 °C cold water, 50 °C warm water and 55 °C primary flow | numeric | l/min | — |
| EF018860 | Max. warm water at 10 °C cold water, 50 °C warm water and 60 °C primary flow | numeric | l/min | — |
| EF018861 | Max. warm water at 10 °C cold water, 50 °C warm water and 65 °C primary flow | numeric | l/min | — |
| EF018862 | Max. warm water at 10 °C cold water, 55 °C warm water and 60 °C primary flow | numeric | l/min | — |
| EF018863 | Max. warm water at 10 °C cold water, 55 °C warm water and 65 °C primary flow | numeric | l/min | — |
| EF018864 | Max. warm water at 10 °C cold water, 55 °C warm water and 70 °C primary flow | numeric | l/min | — |
| EF018865 | Max. warm water at 10 °C cold water, 60 °C warm water and 65 °C primary flow | numeric | l/min | — |
| EF018866 | Max. warm water at 10 °C cold water, 60 °C warm water and 70 °C primary flow | numeric | l/min | — |
| EF018867 | Max. warm water at 10 °C cold water, 60 °C warm water and 75 °C primary flow | numeric | l/min | — |
| EF009381 | Tap water power | numeric | kW | — |
| EF009384 | Adjustment range hot water temperature | range | °C | — |
| EF018868 | Max. heating power at 10 Kelvin temperature spread (flow to return) | numeric | kW | — |
| EF018869 | Max. heating power at 4 Kelvin temperature spread (flow to return) | numeric | kW | — |
| EF002286 | Connection supply | alphanumeric | — |
|
| EF023886 | Nominal diameter of supply | alphanumeric | — |
|
| EF020469 | Outer pipe diameter supply | numeric | mm | — |
| EF002287 | Connection return | alphanumeric | — |
|
| EF023887 | Nominal diameter return | alphanumeric | — |
|
| EF020475 | Outer pipe diameter return | numeric | mm | — |
| EF002267 | Connection feed/return heating | alphanumeric | — |
|
| EF023807 | Nominal diameter heating | alphanumeric | — |
|
| EF020142 | Outer pipe diameter heating | numeric | mm | — |
| EF021387 | Hot tap water connection | alphanumeric | — |
|
| EF010896 | Nominal diameter hot tap water | alphanumeric | — |
|
| EF020504 | Outer pipe diameter hot tap water | numeric | mm | — |
| EF021386 | Cold tap water connection | alphanumeric | — |
|
| EF020013 | Nominal diameter cold tap water | alphanumeric | — |
|
| EF020499 | Outer pipe diameter cold tap water | numeric | mm | — |
| EF021065 | With circulation connection | logical | — | — |
| EF021389 | Circulation pipe connection | alphanumeric | — |
|
| EF015476 | Connection size circulation pipe | alphanumeric | — |
|
| EF021119 | With hot tap water preference | logical | — | — |
| EF015398 | With electric reheater | logical | — | — |
| EF015400 | With differential pressure regulator | logical | — | — |
| EF000687 | Keep-warm setting | logical | — | — |
| EF001709 | Controller | alphanumeric | — |
|
| EF015469 | Flow regulator | logical | — | — |
| EF022987 | With dirt trap | logical | — | — |
| EF002222 | With safety valve | logical | — | — |
| EF015494 | Zone valve | logical | — | — |
| EF021057 | With insulation | logical | — | — |
| EF000040 | Height | numeric | mm | — |
| EF000008 | Width | numeric | mm | — |
| EF000049 | Depth | numeric | mm | — |
| EFDE0048 | DVGW quality mark for gas | logical | — | — |
| EFDE0049 | DVGW quality mark for water | logical | — | — |
| EFNL0005 | CW label | numeric | — | — |
| EFSE0002 | Type approval according to BBR/EKS | logical | — | — |
Requirement levels are not part of this standard and are not shown.
Change history
Per-class history is not reported. Compare releases to see what changed between versions.