etim 10.0 · Class
EC011285Heat recovery unit (residential)
Definition not reported by the standard.
Synonyms: HRV, Heat recovery unit (residential), Heat recovery unit for domestic construction, Heat recovery unit for housing construction, Heat recovery unit for residential construction, Heat recovery unit for single family house, Heat recovery ventilator for domestic construction, Ventilation appliance
- Stable identifier
etim:EC011285- Permalink
- /classifications/etim/10.0/EC011285
- Parent
- EG015170 Air treatment
- Class revision in the standard
- 6
Properties (80)
| Code | Label (EN) | Type | Unit | Allowed values |
|---|---|---|---|---|
| EF002205 | Heat recovery by | alphanumeric | — |
|
| EF001596 | Housing material | alphanumeric | — |
|
| EF024143 | Housing material quality | alphanumeric | — |
|
| EF020003 | Material heat exchanger | alphanumeric | — |
|
| EF000664 | Suitable for wall mounting | logical | — | — |
| EF021180 | Suitable for ceiling mounting | logical | — | — |
| EF025108 | Suitable for floor mounting | logical | — | — |
| EF019477 | Suitable for mounting in suspended ceiling | logical | — | — |
| EF019478 | Suitable for mounting in an attic | logical | — | — |
| EF015867 | Left/right orientation reversible | logical | — | — |
| EF014851 | Max. air volume at 50 Pa | numeric | m³/h | — |
| EF014959 | Max. air volume at 100 Pa | numeric | m³/h | — |
| EF014960 | Max. air volume at 150 Pa | numeric | m³/h | — |
| EF014961 | Max. air volume at 200 Pa | numeric | m³/h | — |
| EF014962 | Max. air volume at 250 Pa | numeric | m³/h | — |
| EF014963 | Max. air volume at 300 Pa | numeric | m³/h | — |
| EF018769 | Max. volume flow according to 1254/2014/EU | numeric | m³/h | — |
| EF018770 | Sound power level according to 1254/2014/EU | numeric | dB(A) | — |
| EF017718 | Sound pressure level | numeric | dB(A) | — |
| EF017599 | Power consumption at max. air volume at 100 Pa | numeric | W | — |
| EF017601 | Thermal efficiency at 70 % air volume at 50 Pa | numeric | % | — |
| EF002735 | Type of motor | alphanumeric | — |
|
| EF000213 | Voltage | numeric | V | — |
| EF000034 | Frequency | numeric | Hz | — |
| EF000351 | Number of phases | numeric | — | — |
| EF004149 | Fuse size of the device | numeric | A | — |
| EF025850 | Power electric heating element | range | W | — |
| EF006233 | With thermal overload protection | logical | — | — |
| EF003701 | Electrical connection | alphanumeric | — |
|
| EF017471 | Energy efficiency class according to 1253/2014/EU | alphanumeric | — |
|
| EF003496 | Type of switch | alphanumeric | — |
|
| EF024362 | With digital display | logical | — | — |
| EF014706 | With wired control unit | logical | — | — |
| EF014707 | Suitable for wired control unit | logical | — | — |
| EF021154 | With wireless remote control | logical | — | — |
| EF024361 | Suitable for wireless remote control | logical | — | — |
| EF003057 | Supporting protocol for Modbus | logical | — | — |
| EF012384 | Operation by app | logical | — | — |
| EF014708 | With zone controller | logical | — | — |
| EF014709 | Suitable for zone controller | logical | — | — |
| EF021913 | With heating element | logical | — | — |
| EF017468 | With volatile organic compound (VOC) sensor | logical | — | — |
| EF017469 | Suitable for extra VOC sensor | logical | — | — |
| EF014701 | With external humidity (RH) sensor | logical | — | — |
| EF014700 | With internal humidity (RH) sensor | logical | — | — |
| EF014702 | Suitable for (extra) humidity (RH) sensor | logical | — | — |
| EF013630 | With internal carbon dioxide (CO2) sensor | logical | — | — |
| EF014699 | Suitable for (extra) carbon dioxide (CO2) sensor | logical | — | — |
| EF024407 | Suitable for central heating boiler connection | logical | — | — |
| EF022201 | With bypass | logical | — | — |
| EF014958 | With constant pressure control | logical | — | — |
| EF014957 | With constant volume flow control | logical | — | — |
| EF014956 | Type of frost protection | alphanumeric | — |
|
| EF023195 | Nominal duct diameter | range | mm | — |
| EF014953 | Connections outdoor air side | alphanumeric | — |
|
| EF014954 | Connections residential side | alphanumeric | — |
|
| EF024364 | Residential connection, underside | logical | — | — |
| EF024365 | Residential connection, left side | logical | — | — |
| EF024366 | Residential connection, right side | logical | — | — |
| EF024367 | Residential connection, top | logical | — | — |
| EF024368 | Roof connection, side | logical | — | — |
| EF024369 | Roof connection, top | logical | — | — |
| EF019346 | Max. number of wet zones | numeric | — | — |
| EF013391 | Supply filter according to ISO 16890-1:2016 | alphanumeric | — |
|
| EF014694 | Efficiency supply filter according to ISO 16890-1:2016 | numeric | % | — |
| EF013390 | Exhaust filter according to ISO 16890-1:2016 | alphanumeric | — |
|
| EF013389 | Efficiency exhaust filter according to ISO 16890-1:2016 | numeric | % | — |
| EF000040 | Height | numeric | mm | — |
| EF000008 | Width | numeric | mm | — |
| EF000049 | Depth | numeric | mm | — |
| EF005474 | Degree of protection (IP) | alphanumeric | — |
|
| EF000167 | Weight | numeric | kg | — |
| EFFR0017 | Suitable for a one-room dwelling acc. to decree nr. 87-149 and law 96-1107 | logical | — | — |
| EFFR0018 | Suitable for a two-room dwelling acc. to decree nr. 87-149 and law 96-1107 | logical | — | — |
| EFFR0019 | Suitable for a three-room dwelling acc. to decree nr. 87-149 and law 96-1107 | logical | — | — |
| EFFR0020 | Suitable for a four-room dwelling acc. to decree nr. 87-149 and law 96-1107 | logical | — | — |
| EFFR0021 | Suitable for a five-room dwelling acc. to decree nr. 87-149 and law 96-1107 | logical | — | — |
| EFFR0022 | Suitable for a six-room dwelling acc. to decree nr. 87-149 and law 96-1107 | logical | — | — |
| EFFR0023 | Suitable for a seven-room dwelling acc. to decree nr. 87-149 and law 96-1107 | logical | — | — |
| EFFR0027 | Weighted average power according to RT 2005 | numeric | W-Th-C | — |
Requirement levels are not part of this standard and are not shown.
Change history
Per-class history is not reported. Compare releases to see what changed between versions.