Hierarchy

etim 10.0 · Class

EC004556HRC fuse

Definition not reported by the standard.

Synonyms: HRC fuse, HRC fuse with bolted, offset blade or flush end connections

Stable identifier
etim:EC004556
Class revision in the standard
2

Properties (13)

Properties of EC004556 in English
CodeLabel (EN)TypeUnitAllowed values
EF017676Fuse system according to IEC 60269alphanumeric—
  • EV024215 Fuse system A
  • EV024216 Fuse system B
  • EV024217 Fuse system C
  • EV024221 IEC 60269-4 flush end connections type A
  • EV024222 IEC 60269-4 flush end connections type B
  • EV024218 Fuse system E
  • EV024219 Fuse system G
  • EV024220 Fuse system I
  • EV000154 Other
EF015865Fuse construction type according to IEC 60269alphanumeric—
  • EV023451 0000
  • EV005311 000
  • EV008738 00
  • EV000601 0
  • EV000599 1
  • EV000600 2
  • EV000069 3
  • EV000070 4
  • EV002392 5
  • EV010732 A1
  • EV010733 A2
  • EV010734 A3
  • EV010731 A4
  • EV013939 B1
  • EV010533 B2
  • EV019327 B3
  • EV019271 B4
  • EV014178 C1
  • EV014179 C2
  • EV014180 C3
  • EV013083 D1
  • EV020905 E1
  • EV012528 F1
  • EV012529 F2
  • EV012947 F3
  • EV020890 J
  • EV018427 01XL
  • EV018428 1XL
  • EV018429 2XL
  • EV018430 01L
  • EV018431 1L
  • EV018432 2L
  • EV018433 3L
  • EV000141 L
  • EV005864 U
  • EV000154 Other
EF000143Type of currentalphanumeric—
  • EV000460 AC
  • EV000461 DC
  • EV000509 AC/DC
EF007682Rated voltage ACnumericV—
EF012281Rated voltage DCnumericV—
EF000227Rated currentnumericA—
EF002572Utilization category according to IEC 60269alphanumeric—
  • EV019070 gG
  • EV018418 gM
  • EV005307 aM
  • EV005308 gR
  • EV005309 aR
  • EV011642 gPV
  • EV011643 gB
  • EV011644 gTr
  • EV018425 gBat
  • EV018424 aBat
  • EV018419 gU
  • EV000154 Other
EF005617Breaking capacitynumerickA—
EF000931Colour codealphanumeric—
  • EV000206 Black
  • EV000080 Blue
  • EV000083 Brown
  • EV000235 Green
  • EV000234 Yellow
  • EV000233 Red
  • EV000202 White
  • EV000154 Other
  • EV000494 None
EF004473Type of fuse status indicatoralphanumeric—
  • EV007553 Centre fuse status indicator
  • EV007782 Top fuse status indicator
  • EV007471 Combination fuse status indicator
  • EV000154 Other
  • EV000494 None
EF012389Power loss at rated currentnumericW—
EF021553Mounting holesalphanumeric—
  • EV009088 M3
  • EV009090 M4
  • EV008589 M5
  • EV009091 M6
  • EV008314 M8
  • EV004314 M10
  • EV004315 M12
  • EV000154 Other
EF021151Centre-to-centre distance of connectionsnumericmm—

Requirement levels are not part of this standard and are not shown.