Skip to content
Sign in

ETIM technical information model, English master (unofficial mirror)

License:ODC-By-1.0Community · the product.cloud project (unofficial mirror)Updated · latest release 10.0
  • Validated
  • Community maintained
About access and trust
Open
Immediately usable under the displayed license. Access is separate from the license.
License
ODC-By-1.0 governs use, including for open repositories.
You
No entitlement needed: the content is open.
Validated
Required rulepack checks passed for the named revision.
Community maintained
Maintained by contributors, not the named product authority.
Release 10.0 — pinned
Follow0 Use repository
Hierarchy

etim 10.0 · Class

EC001757Battery for renewable energy systems

Definition not reported by the standard.

Synonyms: Accu, Battery, Battery for hydropower systems, Battery for renewable energy systems, Battery for solar power systems, Battery for water power systems, Battery for waterpower systems, Battery for wind power systems, Rechargeable battery, Solar-battery, Traction battery

Stable identifier
etim:EC001757
Class revision in the standard
9

Properties (24)

Properties of EC001757 in English
CodeLabel (EN)TypeUnitAllowed values
EF000010Modelalphanumeric—
  • EV003088 Lithium
  • EV007507 Lithium-ion
  • EV001141 Nickel cadmium
  • EV002692 Nickel metal hydride
  • EV000154 Other
EF000187Voltage typealphanumeric—
  • EV000460 AC
  • EV000461 DC
EF003983Operating voltagerangeV—
EF000351Number of phasesnumeric——
EF012596Nominal battery capacitynumerickWh—
EF012483Usable battery capacitynumerickWh—
EF019351Nominal charging/discharging currentnumericA—
EF019350C-ratenumeric——
EF015874Max. efficiencynumeric%—
EF004662European efficiencynumeric%—
EF002386Ambient temperaturerange°C—
EF009254Cooling methodalphanumeric—
  • EV025243 Active cooling (ventilator)
  • EV025244 Active cooling (cooling liquid)
  • EV025245 Passive cooling
EF000008Widthnumericmm—
EF000040Heightnumericmm—
EF000049Depthnumericmm—
EF012468Suitable for emergency powerlogical——
EF012484Max. depth of dischargenumeric%—
EF012485Number of complete charge cyclesnumeric——
EF011884Suitable for indoor installationlogical——
EF011885Suitable for outdoor installationlogical——
EF023900Allowable relative humidityrange%—
EF019353Max. altitude of installation location (above sea level)numericm—
EF005474Degree of protection (IP)alphanumeric—
  • EV006405 IP20
  • EV006610 IP43
  • EV006419 IP54
  • EV006420 IP55
  • EV006421 IP65
  • EV006422 IP66
  • EV006423 IP67
  • EV000154 Other
EF000167Weightnumerickg—

Requirement levels are not part of this standard and are not shown.

Change history

Per-class history is not reported. Compare releases to see what changed between versions.

    Data: ETIM International · ODC-By-1.0