etim 10.0 · Class
EC001423PLC communication module
Definition not reported by the standard.
Synonyms: Extension module, Interface, PLC communication module, Serial interface
- Stable identifier
etim:EC001423- Permalink
- /classifications/etim/10.0/EC001423
- Class revision in the standard
- 8
Properties (68)
| Code | Label (EN) | Type | Unit | Allowed values |
|---|---|---|---|---|
| EF003020 | Number of HW-interfaces industrial Ethernet | numeric | — | — |
| EF006932 | Number of interfaces PROFINET | numeric | — | — |
| EF017563 | Number of HW-interfaces CAN | numeric | — | — |
| EF003021 | Number of HW-interfaces RS-232 | numeric | — | — |
| EF003022 | Number of HW-interfaces RS-422 | numeric | — | — |
| EF003023 | Number of HW-interfaces RS-485 | numeric | — | — |
| EF003024 | Number of HW-interfaces serial TTY | numeric | — | — |
| EF003025 | Number of HW-interfaces USB | numeric | — | — |
| EF003026 | Number of HW-interfaces parallel | numeric | — | — |
| EF006933 | Number of HW-interfaces wireless | numeric | — | — |
| EF003027 | Number of HW-interfaces other | numeric | — | — |
| EF003028 | With optical interface | logical | — | — |
| EF017564 | Supporting protocol for EtherCAT | logical | — | — |
| EF003050 | Supporting protocol for TCP/IP | logical | — | — |
| EF003052 | Supporting protocol for PROFIBUS | logical | — | — |
| EF003053 | Supporting protocol for CAN | logical | — | — |
| EF003054 | Supporting protocol for INTERBUS | logical | — | — |
| EF003051 | Supporting protocol for ASI | logical | — | — |
| EF003055 | Supporting protocol for KNX | logical | — | — |
| EF003057 | Supporting protocol for Modbus | logical | — | — |
| EF003058 | Supporting protocol for Data-Highway | logical | — | — |
| EF003059 | Supporting protocol for DeviceNet | logical | — | — |
| EF003060 | Supporting protocol for SUCONET | logical | — | — |
| EF003017 | Supporting protocol for LON | logical | — | — |
| EF007525 | Supporting protocol for PROFINET IO | logical | — | — |
| EF007524 | Supporting protocol for PROFINET CBA | logical | — | — |
| EF006657 | Supporting protocol for SERCOS | logical | — | — |
| EF007522 | Supporting protocol for Foundation Fieldbus | logical | — | — |
| EF007521 | Supporting protocol for EtherNet/IP | logical | — | — |
| EF007519 | Supporting protocol for AS-Interface Safety at Work | logical | — | — |
| EF007520 | Supporting protocol for DeviceNet Safety | logical | — | — |
| EF006662 | Supporting protocol for INTERBUS-Safety | logical | — | — |
| EF007526 | Supporting protocol for PROFIsafe | logical | — | — |
| EF007527 | Supporting protocol for SafetyBUS p | logical | — | — |
| EF003062 | Supporting protocol for other bus systems | logical | — | — |
| EF007178 | Radio standard Bluetooth | logical | — | — |
| EF007179 | Radio standard WLAN 802.11 | logical | — | — |
| EF008523 | Radio standard GPRS | logical | — | — |
| EF008524 | Radio standard GSM | logical | — | — |
| EF008525 | Mobile communications standard 3G (UMTS) | logical | — | — |
| EF007298 | IO link master | logical | — | — |
| EF003156 | Redundancy | logical | — | — |
| EF008225 | Type of data transmission | alphanumeric | — |
|
| EF003271 | Transmission rate | numeric | kBit/s | — |
| EF003272 | With potential separation | logical | — | — |
| EF009889 | SIL according to IEC 61508 | alphanumeric | — |
|
| EF001597 | Suitable for safety functions | logical | — | — |
| EF007399 | Performance level according to EN ISO 13849-1 | alphanumeric | — |
|
| EF004141 | Appendant operation agent (Ex ia) | logical | — | — |
| EF004142 | Appendant operation agent (Ex ib) | logical | — | — |
| EF003997 | Explosion safety category for gas | alphanumeric | — |
|
| EF003998 | Explosion safety category for dust | alphanumeric | — |
|
| EF017622 | Certified for UL hazardous location class I | logical | — | — |
| EF017625 | Certified for UL hazardous location class II | logical | — | — |
| EF017627 | Certified for UL hazardous location class III | logical | — | — |
| EF000346 | Power consumption | numeric | W | — |
| EF017628 | Certified for UL hazardous location division 1 | logical | — | — |
| EF017629 | Certified for UL hazardous location division 2 | logical | — | — |
| EF017632 | Certified for UL hazardous location group A (acetylene) | logical | — | — |
| EF017633 | Certified for UL hazardous location group B (hydrogen) | logical | — | — |
| EF017635 | Certified for UL hazardous location group C (ethylene) | logical | — | — |
| EF017636 | Certified for UL hazardous location group D (propane) | logical | — | — |
| EF017637 | Certified for UL hazardous location group E (metal dusts) | logical | — | — |
| EF017638 | Certified for UL hazardous location group F (carbonaceous dusts) | logical | — | — |
| EF017639 | Certified for UL hazardous location group G (non-conductive dusts) | logical | — | — |
| EF000008 | Width | numeric | mm | — |
| EF000040 | Height | numeric | mm | — |
| EF000049 | Depth | numeric | mm | — |
Requirement levels are not part of this standard and are not shown.
Change history
Per-class history is not reported. Compare releases to see what changed between versions.