etim 10.0 · Class
EC001412Graphic panel
Definition not reported by the standard.
Synonyms: Graphic panel
- Stable identifier
etim:EC001412- Permalink
- /classifications/etim/10.0/EC001412
- Class revision in the standard
- 9
Properties (89)
| Code | Label (EN) | Type | Unit | Allowed values |
|---|---|---|---|---|
| EF007532 | Supply voltage AC 50 Hz | range | V | — |
| EF007533 | Supply voltage AC 60 Hz | range | V | — |
| EF007534 | Supply voltage DC | range | V | — |
| EF002991 | Voltage type (supply voltage) | alphanumeric | — |
|
| EF000346 | Power consumption | numeric | W | — |
| EF003020 | Number of HW-interfaces industrial Ethernet | numeric | — | — |
| EF006932 | Number of interfaces PROFINET | numeric | — | — |
| EF003021 | Number of HW-interfaces RS-232 | numeric | — | — |
| EF003022 | Number of HW-interfaces RS-422 | numeric | — | — |
| EF003023 | Number of HW-interfaces RS-485 | numeric | — | — |
| EF003024 | Number of HW-interfaces serial TTY | numeric | — | — |
| EF003025 | Number of HW-interfaces USB | numeric | — | — |
| EF003026 | Number of HW-interfaces parallel | numeric | — | — |
| EF006933 | Number of HW-interfaces wireless | numeric | — | — |
| EF003027 | Number of HW-interfaces other | numeric | — | — |
| EF003121 | With SW interfaces | logical | — | — |
| EF017564 | Supporting protocol for EtherCAT | logical | — | — |
| EF003050 | Supporting protocol for TCP/IP | logical | — | — |
| EF003052 | Supporting protocol for PROFIBUS | logical | — | — |
| EF003053 | Supporting protocol for CAN | logical | — | — |
| EF003054 | Supporting protocol for INTERBUS | logical | — | — |
| EF003051 | Supporting protocol for ASI | logical | — | — |
| EF003055 | Supporting protocol for KNX | logical | — | — |
| EF003057 | Supporting protocol for Modbus | logical | — | — |
| EF003058 | Supporting protocol for Data-Highway | logical | — | — |
| EF003059 | Supporting protocol for DeviceNet | logical | — | — |
| EF003060 | Supporting protocol for SUCONET | logical | — | — |
| EF003017 | Supporting protocol for LON | logical | — | — |
| EF007525 | Supporting protocol for PROFINET IO | logical | — | — |
| EF007524 | Supporting protocol for PROFINET CBA | logical | — | — |
| EF006657 | Supporting protocol for SERCOS | logical | — | — |
| EF007522 | Supporting protocol for Foundation Fieldbus | logical | — | — |
| EF007521 | Supporting protocol for EtherNet/IP | logical | — | — |
| EF007519 | Supporting protocol for AS-Interface Safety at Work | logical | — | — |
| EF007520 | Supporting protocol for DeviceNet Safety | logical | — | — |
| EF006662 | Supporting protocol for INTERBUS-Safety | logical | — | — |
| EF007526 | Supporting protocol for PROFIsafe | logical | — | — |
| EF007527 | Supporting protocol for SafetyBUS p | logical | — | — |
| EF003062 | Supporting protocol for other bus systems | logical | — | — |
| EF007178 | Radio standard Bluetooth | logical | — | — |
| EF007179 | Radio standard WLAN 802.11 | logical | — | — |
| EF008523 | Radio standard GPRS | logical | — | — |
| EF008524 | Radio standard GSM | logical | — | — |
| EF008525 | Mobile communications standard 3G (UMTS) | logical | — | — |
| EF007298 | IO link master | logical | — | — |
| EF008244 | Type of display | alphanumeric | — |
|
| EF003097 | Colour display | logical | — | — |
| EF003098 | Number of colours of the display | numeric | — | — |
| EF008515 | Number of grey-scales/blue-scales of display | numeric | — | — |
| EF002032 | Screen diagonal | numeric | inch | — |
| EF003099 | Number of pixels, horizontal | numeric | — | — |
| EF003100 | Number of pixels, vertical | numeric | — | — |
| EF003108 | Usable project memory/user memory | numeric | kByte | — |
| EF003105 | With numeric keyboard | logical | — | — |
| EF003106 | With alpha numeric keyboard | logical | — | — |
| EF003103 | Number of function buttons, programmable | numeric | — | — |
| EF009259 | Number of buttons with LED | numeric | — | — |
| EF009260 | Number of system buttons | numeric | — | — |
| EF010884 | Touch technology | alphanumeric | — |
|
| EF003109 | With message indication | logical | — | — |
| EF003110 | With message system (incl. buffer and confirmation) | logical | — | — |
| EF003111 | Process value representation (output) possible | logical | — | — |
| EF003112 | Process default value (input) possible | logical | — | — |
| EF003113 | With recipes | logical | — | — |
| EF003114 | Number of password levels | numeric | — | — |
| EF003115 | With printer output | logical | — | — |
| EF003116 | Number of online languages | numeric | — | — |
| EF003117 | Additional software components, loadable | logical | — | — |
| EF003118 | Degree of protection (IP), front side | alphanumeric | — |
|
| EF011961 | Degree of protection (NEMA), front side | alphanumeric | — |
|
| EF017622 | Certified for UL hazardous location class I | logical | — | — |
| EF017625 | Certified for UL hazardous location class II | logical | — | — |
| EF017627 | Certified for UL hazardous location class III | logical | — | — |
| EF017628 | Certified for UL hazardous location division 1 | logical | — | — |
| EF017629 | Certified for UL hazardous location division 2 | logical | — | — |
| EF017632 | Certified for UL hazardous location group A (acetylene) | logical | — | — |
| EF017633 | Certified for UL hazardous location group B (hydrogen) | logical | — | — |
| EF017635 | Certified for UL hazardous location group C (ethylene) | logical | — | — |
| EF017636 | Certified for UL hazardous location group D (propane) | logical | — | — |
| EF017637 | Certified for UL hazardous location group E (metal dusts) | logical | — | — |
| EF017638 | Certified for UL hazardous location group F (carbonaceous dusts) | logical | — | — |
| EF017639 | Certified for UL hazardous location group G (non-conductive dusts) | logical | — | — |
| EF002393 | Operating temperature | range | °C | — |
| EF003972 | Suitable for rail mounting | logical | — | — |
| EF007020 | Wall mounting/direct mounting | logical | — | — |
| EF001597 | Suitable for safety functions | logical | — | — |
| EF003651 | Width of the front | numeric | mm | — |
| EF003652 | Height of the front | numeric | mm | — |
| EF000218 | Built-in depth | numeric | mm | — |
Requirement levels are not part of this standard and are not shown.
Change history
Per-class history is not reported. Compare releases to see what changed between versions.