Release 10.0 — pinned
Follow0 Use repository
Hierarchy

etim 10.0 · Class

EC000905Earth leakage circuit breaker

Definition not reported by the standard.

Synonyms: Earth leakage circuit breaker, Earth leakage switch, RCBO

Stable identifier
etim:EC000905
Class revision in the standard
10

Properties (30)

Properties of EC000905 in English
CodeLabel (EN)TypeUnitAllowed values
EF008618Number of poles (total)numeric——
EF005548Number of protected polesnumeric——
EF000228Rated voltagenumericV—
EF001366Rated insulation voltage UinumericV—
EF011980Rated impulse withstand voltage UimpnumerickV—
EF000227Rated currentnumericA—
EF002358Rated fault currentnumericA—
EF000003Mounting methodalphanumeric—
  • EV006541 Intermediate plug
  • EV000134 Built-in
  • EV000242 DIN rail
  • EV000945 Surface mounting
  • EV000154 Other
EF002560Leakage current typealphanumeric—
  • EV000896 A
  • EV000460 AC
  • EV000074 B
  • EV010681 B+
  • EV000334 F
  • EV000154 Other
EF002568Current limiting classnumeric——
EF005387Power lossnumericW—
EF012628Rated short-circuit breaking capacity according to EN 61009numerickA—
EF006065Rated short-circuit breaking capacity according to IEC 60947-2numerickA—
EF011981Rated short-circuit breaking capacity Icn according to EN 61009-1numerickA—
EF012587Disconnection characteristicalphanumeric—
  • EV003978 Undelayed
  • EV015071 Short-time delayed
  • EV015072 Selective
  • EV000154 Other
EF002564Surge current capacitynumerickA—
EF000187Voltage typealphanumeric—
  • EV000460 AC
  • EV000509 AC/DC
  • EV000461 DC
EF005455Frequencyalphanumeric—
  • EV008013 50 Hz
  • EV008017 60 Hz
  • EV008015 50/60 Hz
  • EV000154 Other
EF000889Release characteristicalphanumeric—
  • EV000896 A
  • EV000074 B
  • EV000084 C
  • EV000413 D
  • EV000647 E
  • EV000247 K
  • EV000154 Other
EF005997Concurrently switching neutral conductorlogical——
EF007385With interlocking devicelogical——
EF002569Overvoltage categorynumeric——
EF002570Pollution degreenumeric——
EF007515Ambient temperature during operatingrange°C—
EF002950Width in number of modular spacingsnumeric——
EF000218Built-in depthnumericmm—
EF009497Anti-nuisance tripping versionlogical——
EF005474Degree of protection (IP)alphanumeric—
  • EV006404 IP00
  • EV006606 IP10
  • EV006607 IP12
  • EV006405 IP20
  • EV006406 IP21
  • EV006608 IP22
  • EV006407 IP23
  • EV006408 IP24
  • EV006409 IP2X
  • EV006410 IP30
  • EV006411 IP31
  • EV006412 IP32
  • EV006609 IP33
  • EV006413 IP34
  • EV006414 IP3X
  • EV006415 IP40
  • EV006416 IP41
  • EV006417 IP42
  • EV006610 IP43
  • EV006418 IP44
  • EV006611 IP45
  • EV006612 IP50
  • EV006613 IP52
  • EV006614 IP53
  • EV006419 IP54
  • EV006420 IP55
  • EV006615 IP56
  • EV006616 IP57
  • EV006617 IP58
  • EV006618 IP64
  • EV006421 IP65
  • EV006422 IP66
  • EV006423 IP67
  • EV006619 IP68
  • EV006620 IPX0
  • EV006621 IPX4
  • EV006622 IPX7
  • EV000154 Other
EF007337Connectable conductor cross section solid-corerangemm²—
EF007343Connectable conductor cross section multi-wiredrangemm²—

Requirement levels are not part of this standard and are not shown.

Change history

Per-class history is not reported. Compare releases to see what changed between versions.

    Data: ETIM International · ODC-By-1.0