etim 10.0 · Class
EC000722On-floor installation duct
Definition not reported by the standard.
Synonyms: Cable bridge, Car passage duct, Installation duct, On-floor installation duct, On-floor installation duct for vehicular passage, Protector rubber, Truck passage duct
- Stable identifier
etim:EC000722- Permalink
- /classifications/etim/10.0/EC000722
- Class revision in the standard
- 9
Properties (30)
| Code | Label (EN) | Type | Unit | Allowed values |
|---|---|---|---|---|
| EF000008 | Width | numeric | mm | — |
| EF000040 | Height | numeric | mm | — |
| EF001438 | Length | numeric | mm | — |
| EF000259 | Number of channels | numeric | — | — |
| EF021719 | With cover cap | logical | — | — |
| EF002169 | Material | alphanumeric | — |
|
| EF001257 | Material quality | alphanumeric | — |
|
| EF008217 | Permitted cable diameter | range | mm | — |
| EF000007 | Colour | alphanumeric | — |
|
| EF000116 | RAL-number | numeric | — | — |
| EF004545 | Bottom perforation | logical | — | — |
| EF006189 | Slotted hole | logical | — | — |
| EF023515 | With fixation | logical | — | — |
| EF007551 | Demountable | logical | — | — |
| EF000434 | Self-adhesive | logical | — | — |
| EF007728 | Sealing lip | logical | — | — |
| EF006007 | With anti-slip layer | logical | — | — |
| EF010115 | Reflective | logical | — | — |
| EF023790 | Anti-bacterial treatment | logical | — | — |
| EF000025 | Halogen free | logical | — | — |
| EF018168 | Fuel- and oil resistant | logical | — | — |
| EF000258 | Max. load capacity | numeric | t | — |
| EF017604 | Resistance to vertical load applied in a small surface according IEC 61084-2-2 | numeric | N | — |
| EF017605 | Resistance to vertical load applied in a large surface according IEC 61084-2-2 | numeric | N | — |
| EF025631 | Suitable for car | logical | — | — |
| EF025632 | Suitable for truck | logical | — | — |
| EF001742 | Operating temperature | range | °C | — |
| EF005474 | Degree of protection (IP) | alphanumeric | — |
|
| EF004293 | Impact strength | alphanumeric | — |
|
| EF005660 | Bending strength | alphanumeric | — |
|
Requirement levels are not part of this standard and are not shown.
Change history
Per-class history is not reported. Compare releases to see what changed between versions.