etim 10.0 · Class
EC000042Miniature circuit breaker (MCB)
Definition not reported by the standard.
Synonyms: Automatic protection, Automaton, Built-in device, Circuit breaker, Circuit-breakers, Explosion proof MCB, Explosion proof miniature circuit breaker (MCB), Flex omat, Flexomat, MCB, Mini circuit breaker, Miniature circuit breaker (MCB), Over current switch, Overcurrent switch
- Stable identifier
etim:EC000042- Permalink
- /classifications/etim/10.0/EC000042
- Class revision in the standard
- 9
Properties (27)
| Code | Label (EN) | Type | Unit | Allowed values |
|---|---|---|---|---|
| EF000218 | Built-in depth | numeric | mm | — |
| EF000889 | Release characteristic | alphanumeric | — |
|
| EF008618 | Number of poles (total) | numeric | — | — |
| EF005548 | Number of protected poles | numeric | — | — |
| EF000227 | Rated current | numeric | A | — |
| EF000228 | Rated voltage | numeric | V | — |
| EF001366 | Rated insulation voltage Ui | numeric | V | — |
| EF011980 | Rated impulse withstand voltage Uimp | numeric | kV | — |
| EF009556 | Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V | numeric | kA | — |
| EF000187 | Voltage type | alphanumeric | — |
|
| EF009555 | Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V | numeric | kA | — |
| EF009557 | Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V | numeric | kA | — |
| EF009558 | Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V | numeric | kA | — |
| EF000416 | Frequency | range | Hz | — |
| EF005387 | Power loss | numeric | W | — |
| EF002568 | Current limiting class | numeric | — | — |
| EF007517 | Flush-mounted installation | logical | — | — |
| EF005997 | Concurrently switching neutral conductor | logical | — | — |
| EF002569 | Overvoltage category | numeric | — | — |
| EF002570 | Pollution degree | numeric | — | — |
| EF008148 | Additional equipment possible | logical | — | — |
| EF002950 | Width in number of modular spacings | numeric | — | — |
| EF005474 | Degree of protection (IP) | alphanumeric | — |
|
| EF007515 | Ambient temperature during operating | range | °C | — |
| EF007343 | Connectable conductor cross section multi-wired | range | mm² | — |
| EF007337 | Connectable conductor cross section solid-core | range | mm² | — |
| EF004663 | Explosion-proof | logical | — | — |
Requirement levels are not part of this standard and are not shown.
Change history
Per-class history is not reported. Compare releases to see what changed between versions.