Hierarchy

etim 5.0 · Class

EC002591Hinge switchen fallback: no German translation

Definition not reported by the standard.

Synonyms: End switchen fallback: no German translation, Hinge switchen fallback: no German translation, Switchen fallback: no German translation

Stable identifier
etim:EC002591
Class revision in the standard
5

Properties (28)

Properties of EC002591 in German with English for comparison
CodeLabel (DE)Label (EN)TypeUnitAllowed values
EF001602With status indicationen fallback: no German translationWith status indicationlogical——
EF001597Suited for safety functionsen fallback: no German translationSuited for safety functionslogical——
EF006976Type of control elementen fallback: no German translationType of control elementalphanumeric—
  • EV009501 Full shaften fallback: no German translation
  • EV009284 Hollow shaften fallback: no German translation
  • EV000154 Otheren fallback: no German translation
  • EV000494 Noneen fallback: no German translation
EF006694Forced openingen fallback: no German translationForced openinglogical——
EF006940Number of safety auxiliary contactsen fallback: no German translationNumber of safety auxiliary contactsnumeric——
EF008255Number of contacts as normally closed contacten fallback: no German translationNumber of contacts as normally closed contactnumeric——
EF008256Number of contacts as normally open contacten fallback: no German translationNumber of contacts as normally open contactnumeric——
EF008257Number of contacts as change-over contacten fallback: no German translationNumber of contacts as change-over contactnumeric——
EF003591Type of switching contacten fallback: no German translationType of switching contactalphanumeric—
  • EV004165 Slow-action switchen fallback: no German translation
  • EV000533 Quick-break switchen fallback: no German translation
  • EV009411 Slow-action switch and quick-break switchen fallback: no German translation
  • EV000154 Otheren fallback: no German translation
EF007094Width sensoren fallback: no German translationWidth sensornumericmm—
EF007283Height of sensoren fallback: no German translationHeight of sensornumericmm—
EF007334Length of sensoren fallback: no German translationLength of sensornumericmm—
EF007084Rated operation current Ie at AC-15, 24 Ven fallback: no German translationRated operation current Ie at AC-15, 24 VnumericA—
EF007082Rated operation current Ie at AC-15, 125 Ven fallback: no German translationRated operation current Ie at AC-15, 125 VnumericA—
EF001385Rated operation current Ie at AC-15, 230 Ven fallback: no German translationRated operation current Ie at AC-15, 230 VnumericA—
EF007087Rated operation current Ie at DC-13, 24 Ven fallback: no German translationRated operation current Ie at DC-13, 24 VnumericA—
EF007085Rated operation current Ie at DC-13, 125 Ven fallback: no German translationRated operation current Ie at DC-13, 125 VnumericA—
EF001386Rated operation current Ie at DC-13, 230 Ven fallback: no German translationRated operation current Ie at DC-13, 230 VnumericA—
EF008388Housing according to normen fallback: no German translationHousing according to normalphanumeric—
  • EV010570 DIN EN 50041en fallback: no German translation
  • EV010571 DIN EN 50047en fallback: no German translation
  • EV000154 Otheren fallback: no German translation
EF004008Construction type housingen fallback: no German translationConstruction type housingalphanumeric—
  • EV009378 Cuboiden fallback: no German translation
  • EV006688 Special constructionen fallback: no German translation
  • EV000154 Otheren fallback: no German translation
EF001596Material housingen fallback: no German translationMaterial housingalphanumeric—
  • EV000139 Plasticen fallback: no German translation
  • EV000914 Metalen fallback: no German translation
  • EV000154 Otheren fallback: no German translation
EF001601Coating housingen fallback: no German translationCoating housingalphanumeric—
  • EV000112 Anodiseden fallback: no German translation
  • EV000113 Varnisheden fallback: no German translation
  • EV008895 With powder coatingen fallback: no German translation
  • EV000189 Chromium-plateden fallback: no German translation
  • EV000191 Nickel-plateden fallback: no German translation
  • EV000154 Otheren fallback: no German translation
EF003961Type of electric connectionen fallback: no German translationType of electric connectionalphanumeric—
  • EV009298 Cable entry metricalen fallback: no German translation
  • EV009299 Cable entry PGen fallback: no German translation
  • EV009340 With cable preassembleden fallback: no German translation
  • EV009447 Plug-in connection M8en fallback: no German translation
  • EV009444 Plug-in connection M12en fallback: no German translation
  • EV003968 Flat plug-in connectionen fallback: no German translation
  • EV009448 Plug-in connection othersen fallback: no German translation
  • EV000154 Otheren fallback: no German translation
EF003997Explosion safety category for gasen fallback: no German translationExplosion safety category for gasalphanumeric—
  • EV006561 ATEX gas-ex-protection, Cat. 1Gen fallback: no German translation
  • EV006562 ATEX gas-ex-protection, Cat. 2Gen fallback: no German translation
  • EV006563 ATEX gas-ex-protection, Cat. 3Gen fallback: no German translation
  • EV000154 Otheren fallback: no German translation
  • EV000494 Noneen fallback: no German translation
EF003998Explosion safety category for dusten fallback: no German translationExplosion safety category for dustalphanumeric—
  • EV006564 ATEX dust-ex-protection, Cat. 1Den fallback: no German translation
  • EV006565 ATEX dust-ex-protection, Cat. 2Den fallback: no German translation
  • EV006566 ATEX dust-ex-protection, Cat. 3Den fallback: no German translation
  • EV000154 Otheren fallback: no German translation
  • EV000494 Noneen fallback: no German translation
EF006977Type of interfaceen fallback: no German translationType of interfacealphanumeric—
  • EV006558 AS-Interfaceen fallback: no German translation
  • EV006605 INTERBUSen fallback: no German translation
  • EV004167 PROFIBUSen fallback: no German translation
  • EV000154 Otheren fallback: no German translation
  • EV000494 Noneen fallback: no German translation
EF003956Type of interface for safety communicationen fallback: no German translationType of interface for safety communicationalphanumeric—
  • EV006559 AS-Interface Safety at Worken fallback: no German translation
  • EV006579 DeviceNet Safetyen fallback: no German translation
  • EV009287 INTERBUS-Safetyen fallback: no German translation
  • EV006659 PROFIsafeen fallback: no German translation
  • EV006674 SafetyBUS pen fallback: no German translation
  • EV000154 Otheren fallback: no German translation
  • EV000494 Noneen fallback: no German translation
EF005474Degree of protection (IP)en fallback: no German translationDegree of protection (IP)alphanumeric—
  • EV006404 IP00en fallback: no German translation
  • EV006606 IP10en fallback: no German translation
  • EV006607 IP12en fallback: no German translation
  • EV006405 IP20en fallback: no German translation
  • EV006406 IP21en fallback: no German translation
  • EV006608 IP22en fallback: no German translation
  • EV006407 IP23en fallback: no German translation
  • EV006408 IP24en fallback: no German translation
  • EV006409 IP2Xen fallback: no German translation
  • EV006410 IP30en fallback: no German translation
  • EV006411 IP31en fallback: no German translation
  • EV006412 IP32en fallback: no German translation
  • EV006609 IP33en fallback: no German translation
  • EV006413 IP34en fallback: no German translation
  • EV006414 IP3Xen fallback: no German translation
  • EV006415 IP40en fallback: no German translation
  • EV006416 IP41en fallback: no German translation
  • EV006417 IP42en fallback: no German translation
  • EV006610 IP43en fallback: no German translation
  • EV006418 IP44en fallback: no German translation
  • EV006611 IP45en fallback: no German translation
  • EV006612 IP50en fallback: no German translation
  • EV006613 IP52en fallback: no German translation
  • EV006614 IP53en fallback: no German translation
  • EV006419 IP54en fallback: no German translation
  • EV006420 IP55en fallback: no German translation
  • EV006615 IP56en fallback: no German translation
  • EV006616 IP57en fallback: no German translation
  • EV006617 IP58en fallback: no German translation
  • EV006618 IP64en fallback: no German translation
  • EV006421 IP65en fallback: no German translation
  • EV009288 IP66/IP67en fallback: no German translation
  • EV006422 IP66en fallback: no German translation
  • EV006423 IP67en fallback: no German translation
  • EV009289 IP67Ken fallback: no German translation
  • EV006619 IP68en fallback: no German translation
  • EV006620 IPX0en fallback: no German translation
  • EV006621 IPX4en fallback: no German translation
  • EV006622 IPX7en fallback: no German translation
  • EV000154 Otheren fallback: no German translation

Requirement levels are not part of this standard and are not shown.