etim 5.0 · Class
EC001444Insulation and earth fault monitoring relayen fallback: no German translation
Definition not reported by the standard.
Synonyms: Insulation and earth fault monitoring relayen fallback: no German translation, Relayen fallback: no German translation
- Stable identifier
etim:EC001444- Permalink
- /classifications/etim/5.0/EC001444
- Parent
- EG000019 Relais
- Class revision in the standard
- 4
Properties (20)
| Code | Label (DE) | Label (EN) | Type | Unit | Allowed values |
|---|---|---|---|---|---|
| EF003961 | Type of electric connectionen fallback: no German translation | Type of electric connection | alphanumeric | — |
|
| EF003978 | Rated control supply voltage Us at AC 50HZen fallback: no German translation | Rated control supply voltage Us at AC 50HZ | range | V | — |
| EF003979 | Rated control supply voltage Us at AC 60HZen fallback: no German translation | Rated control supply voltage Us at AC 60HZ | range | V | — |
| EF003980 | Rated control supply voltage Us at DCen fallback: no German translation | Rated control supply voltage Us at DC | range | V | — |
| EF008242 | Voltage type for actuatingen fallback: no German translation | Voltage type for actuating | alphanumeric | — |
|
| EF003340 | With detachable clampsen fallback: no German translation | With detachable clamps | logical | — | — |
| EF000030 | Functionen fallback: no German translation | Function | alphanumeric | — |
|
| EF003977 | Rated voltageen fallback: no German translation | Rated voltage | range | V | — |
| EF001663 | Rated frequencyen fallback: no German translation | Rated frequency | range | Hz | — |
| EF003419 | Line capacityen fallback: no German translation | Line capacity | numeric | µF | — |
| EF008202 | Response value impedance 1en fallback: no German translation | Response value impedance 1 | range | kOhm | — |
| EF008203 | Response value impedance 2en fallback: no German translation | Response value impedance 2 | range | kOhm | — |
| EF003422 | Indication of insulation valueen fallback: no German translation | Indication of insulation value | logical | — | — |
| EF003423 | Error registration possibleen fallback: no German translation | Error registration possible | logical | — | — |
| EF008255 | Number of contacts as normally closed contacten fallback: no German translation | Number of contacts as normally closed contact | numeric | — | — |
| EF008256 | Number of contacts as normally open contacten fallback: no German translation | Number of contacts as normally open contact | numeric | — | — |
| EF008257 | Number of contacts as change-over contacten fallback: no German translation | Number of contacts as change-over contact | numeric | — | — |
| EF000008 | Widthen fallback: no German translation | Width | numeric | mm | — |
| EF000040 | Heighten fallback: no German translation | Height | numeric | mm | — |
| EF000049 | Depthen fallback: no German translation | Depth | numeric | mm | — |
Requirement levels are not part of this standard and are not shown.
Change history
Per-class history is not reported. Compare releases to see what changed between versions.