etim 5.0 · Class
EC001440Current monitoring relayen fallback: no German translation
Definition not reported by the standard.
Synonyms: Current monitoring relayen fallback: no German translation, Power relayen fallback: no German translation, Relayen fallback: no German translation
- Stable identifier
etim:EC001440- Permalink
- /classifications/etim/5.0/EC001440
- Parent
- EG000019 Relais
- Class revision in the standard
- 4
Properties (26)
| Code | Label (DE) | Label (EN) | Type | Unit | Allowed values |
|---|---|---|---|---|---|
| EF003961 | Type of electric connectionen fallback: no German translation | Type of electric connection | alphanumeric | — |
|
| EF003340 | With detachable clampsen fallback: no German translation | With detachable clamps | logical | — | — |
| EF003405 | Single-phase under current possibleen fallback: no German translation | Single-phase under current possible | logical | — | — |
| EF003406 | Three-phase under current possibleen fallback: no German translation | Three-phase under current possible | logical | — | — |
| EF003407 | Single-phase over current possibleen fallback: no German translation | Single-phase over current possible | logical | — | — |
| EF003408 | Three-phase over current possibleen fallback: no German translation | Three-phase over current possible | logical | — | — |
| EF003394 | Single-phase hysteresis possibleen fallback: no German translation | Single-phase hysteresis possible | logical | — | — |
| EF003395 | Three-phase hysteresis possibleen fallback: no German translation | Three-phase hysteresis possible | logical | — | — |
| EF003409 | Contains function DC-voltage under currenten fallback: no German translation | Contains function DC-voltage under current | logical | — | — |
| EF003410 | Contains function DC-voltage over currenten fallback: no German translation | Contains function DC-voltage over current | logical | — | — |
| EF003411 | Function DC-current hysteresisen fallback: no German translation | Function DC-current hysteresis | logical | — | — |
| EF003978 | Rated control supply voltage Us at AC 50HZen fallback: no German translation | Rated control supply voltage Us at AC 50HZ | range | V | — |
| EF003979 | Rated control supply voltage Us at AC 60HZen fallback: no German translation | Rated control supply voltage Us at AC 60HZ | range | V | — |
| EF003980 | Rated control supply voltage Us at DCen fallback: no German translation | Rated control supply voltage Us at DC | range | V | — |
| EF008242 | Voltage type for actuatingen fallback: no German translation | Voltage type for actuating | alphanumeric | — |
|
| EF000417 | Current measurement rangeen fallback: no German translation | Current measurement range | range | A | — |
| EF008190 | Min. adjustable delay-on energization timeen fallback: no German translation | Min. adjustable delay-on energization time | numeric | s | — |
| EF008189 | Max. permitted delay-on energization timeen fallback: no German translation | Max. permitted delay-on energization time | numeric | s | — |
| EF008192 | Min. adjustable off-delay timeen fallback: no German translation | Min. adjustable off-delay time | numeric | s | — |
| EF008191 | Max. permitted off-delay timeen fallback: no German translation | Max. permitted off-delay time | numeric | s | — |
| EF008255 | Number of contacts as normally closed contacten fallback: no German translation | Number of contacts as normally closed contact | numeric | — | — |
| EF008256 | Number of contacts as normally open contacten fallback: no German translation | Number of contacts as normally open contact | numeric | — | — |
| EF008257 | Number of contacts as change-over contacten fallback: no German translation | Number of contacts as change-over contact | numeric | — | — |
| EF000008 | Widthen fallback: no German translation | Width | numeric | mm | — |
| EF000040 | Heighten fallback: no German translation | Height | numeric | mm | — |
| EF000049 | Depthen fallback: no German translation | Depth | numeric | mm | — |
Requirement levels are not part of this standard and are not shown.
Change history