etim 5.0 · Class
EC001421PLC analogue/digital I/O-moduleen fallback: no German translation
Definition not reported by the standard.
Synonyms: Analogue moduleen fallback: no German translation, Digital moduleen fallback: no German translation, Extension moduleen fallback: no German translation, PLC analogue/digital I/O-moduleen fallback: no German translation
- Stable identifier
etim:EC001421- Permalink
- /classifications/etim/5.0/EC001421
- Class revision in the standard
- 5
Properties (41)
| Code | Label (DE) | Label (EN) | Type | Unit | Allowed values |
|---|---|---|---|---|---|
| EF007532 | Supply voltage AC 50 Hzen fallback: no German translation | Supply voltage AC 50 Hz | range | V | — |
| EF007533 | Supply voltage AC 60 Hzen fallback: no German translation | Supply voltage AC 60 Hz | range | V | — |
| EF007534 | Supply voltage DCen fallback: no German translation | Supply voltage DC | range | V | — |
| EF002991 | Voltage type of supply voltageen fallback: no German translation | Voltage type of supply voltage | alphanumeric | — |
|
| EF001427 | Number of digital inputsen fallback: no German translation | Number of digital inputs | numeric | — | — |
| EF001429 | Number of digital outputsen fallback: no German translation | Number of digital outputs | numeric | — | — |
| EF003030 | Number of analogue inputsen fallback: no German translation | Number of analogue inputs | numeric | — | — |
| EF003031 | Number of analogue outputsen fallback: no German translation | Number of analogue outputs | numeric | — | — |
| EF006652 | Digital in-/outputs, configurableen fallback: no German translation | Digital in-/outputs, configurable | logical | — | — |
| EF001428 | Input current at signal 1en fallback: no German translation | Input current at signal 1 | numeric | mA | — |
| EF007554 | Permitted voltage at inputen fallback: no German translation | Permitted voltage at input | range | V | — |
| EF003033 | Type of voltage (input voltage)en fallback: no German translation | Type of voltage (input voltage) | alphanumeric | — |
|
| EF003601 | Type of digital outputen fallback: no German translation | Type of digital output | alphanumeric | — |
|
| EF003218 | Output current at digital outputen fallback: no German translation | Output current at digital output | numeric | A | — |
| EF003215 | Output voltage at digital outputen fallback: no German translation | Output voltage at digital output | range | V | — |
| EF008222 | Type of output voltageen fallback: no German translation | Type of output voltage | alphanumeric | — |
|
| EF003320 | Short-circuit protection, digital outputs availableen fallback: no German translation | Short-circuit protection, digital outputs available | logical | — | — |
| EF003219 | Analogue input, currenten fallback: no German translation | Analogue input, current | logical | — | — |
| EF003221 | Analogue input, voltageen fallback: no German translation | Analogue input, voltage | logical | — | — |
| EF003222 | Analogue input, resistoren fallback: no German translation | Analogue input, resistor | logical | — | — |
| EF003224 | Analogue input, resistor temperatureen fallback: no German translation | Analogue input, resistor temperature | logical | — | — |
| EF003225 | Analogue input, thermocoupleen fallback: no German translation | Analogue input, thermocouple | logical | — | — |
| EF003575 | Resolution of the analogue inputsen fallback: no German translation | Resolution of the analogue inputs | numeric | Bit | — |
| EF003227 | Analogue input signal configurableen fallback: no German translation | Analogue input signal configurable | logical | — | — |
| EF003234 | Analogue output, currenten fallback: no German translation | Analogue output, current | logical | — | — |
| EF003235 | Analogue output, voltageen fallback: no German translation | Analogue output, voltage | logical | — | — |
| EF003577 | Resolution of the analogue outputsen fallback: no German translation | Resolution of the analogue outputs | numeric | Bit | — |
| EF003236 | Analogue output signal configurableen fallback: no German translation | Analogue output signal configurable | logical | — | — |
| EF003961 | Type of electric connectionen fallback: no German translation | Type of electric connection | alphanumeric | — |
|
| EF002382 | Time delay at signal exchangeen fallback: no German translation | Time delay at signal exchange | range | ms | — |
| EF001597 | Suited for safety functionsen fallback: no German translation | Suited for safety functions | logical | — | — |
| EF006782 | Category according to EN 954-1en fallback: no German translation | Category according to EN 954-1 | alphanumeric | — |
|
| EF004106 | SIL according to IEC 61508en fallback: no German translation | SIL according to IEC 61508 | numeric | — | — |
| EF007399 | Performance level acc. to EN ISO 13849-1en fallback: no German translation | Performance level acc. to EN ISO 13849-1 | alphanumeric | — |
|
| EF004141 | Appendant operation agent (Ex ia)en fallback: no German translation | Appendant operation agent (Ex ia) | logical | — | — |
| EF004142 | Appendant operation agent (Ex ib)en fallback: no German translation | Appendant operation agent (Ex ib) | logical | — | — |
| EF003997 | Explosion safety category for gasen fallback: no German translation | Explosion safety category for gas | alphanumeric | — |
|
| EF003998 | Explosion safety category for dusten fallback: no German translation | Explosion safety category for dust | alphanumeric | — |
|
| EF000008 | Widthen fallback: no German translation | Width | numeric | mm | — |
| EF000040 | Heighten fallback: no German translation | Height | numeric | mm | — |
| EF000049 | Depthen fallback: no German translation | Depth | numeric | mm | — |
Requirement levels are not part of this standard and are not shown.
Change history
Per-class history is not reported. Compare releases to see what changed between versions.